NORMAL.DOT
Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc
Gespeichert am:2003/03/10
max
Version 14
Seite 29 von 87
I N D I V I D U A L M A R K I N G S Y S T E M S
To find the correct settings of tickle power do the following steps:
1. Warm up the tube by engraving some rubber stamps at full power.
2. Take a very laser sensitive material e.g. laser plastics or soft wood.
3. Reduce the acceleration of the X-axis (settings>options>service:password
„name“) to 1.
4. Engrave an image (please use the sample file „Abnahmetest Alu“ on the CD in
the folder Samples\QS Spoolfiles [copy it into the Spool directory and alter the file
properties from „read only“ to „archive“] ) into the wood and have a look on the
edges (please use a low speed).
5. If you see shadows reduce tickle power, if there are none increase tickle power.
To make sure that your changes take effect always click o n apply in the dialog
window.
shadows beside the engraving, caused by too high tickle power
6. Repeat steps 4 to 6 until you´ve found the setting that is necessary to prevent
shadows, but keeps the tube just below firing.
7. Now you´ve adjusted tickle power.
Note: Before you adjust the edit settings of a tube you should always make sure that
tickle power has been set correctly.
For optimum engraving quality a new adjustment of Edit settings and tickle power is
necessary after a certain lifetime of the tube (Recommended after 1000 hours of
operation).