background image

Operating manual – IDS 100

B-2

EN

4. General safety instructions

Please observe the following safety instructions! 
Any non-compliance with these instructions may 
have serious consequences for the health of per-
sons  and  could  result  in  property  damage  and 
damage to the environment. 

Risk of explosion!

 Do not operate the device in potentially flammable or explosive
environments. Do not install it in such environments, either.

 Do not place the device on a flammable surface.

 Remove any inflammable materials and chemicals from the im-
mediate operating environment.

Functional impairment of and damage to the device!

 Do not use the device outdoors.

 Install the device in a stable position.

 Keep the intake and exhaust openings free. 

 Do not cover the device during operation.

 Only disconnect the device from the mains once it has cooled
down completely.

 Do not use any chemicals for cleaning the device.

Risk of injury and damage to property due to defective devices!

 Before each use of the device, check its accessories and connec-
tion parts for possible damages. Do not use any defective devices
or device parts. 

 Do not use the device if you detect any damage to its plug and
cables. Defective power cables represent a serious health threat.

Danger to life through electrical shock!

 Only connect the device to power sources that are in good tech-
nical order. Do not use damaged wall outlets!

 Pull the connection cable out of the wall outlet by pulling it at
its plug. 

 Do not touch electrical connection cables when your hands are
wet!

 Protect the electrical connection cables against damage caused
by, for example, animals.

 Do not carry out any changes or repairs on the device!

 Do not expose the device to any liquids. 

 Do not apply any liquids to the interior of the device. If this does
happen nevertheless, pull out the power cord and have the de-
vice checked by a specialist workshop.

Risk of injury!

 Do not insert any objects into the intake and exhaust opening of
the device.

 Do not reach into the existing openings.

 Do not leave children or animals unattended near the operating
device!

 Do  not  operate  the  device  in  rooms  with  insufficient  supply  of
combustion air.

 Avoid the improper use of fuels.

Risk of environmental pollution!

 Do not let any leaked fuel seep away into the soil and prevent it
from entering the sewer system.

5. Function and product characteristics

The oil heating unit IDS 100 is used to heat up room air in order to achieve 
a fast heating of large rooms. 
The oil heating unit is operated with heating oil. The device features an 
indirect combustion and is provided with an exhaust connection in order 
to discharge the exhaust gas via the chimney.
A selection of two operating modes ensures that the oil heating unit can 
be controlled both manually by the user as well as automatically with the 
support of the thermostat.

6. Technical data

Type IDS 100

Parameter

Value

Article number

1.430.000.140

Electrical connection

230 V

Frequency

50 Hz 

Nominal current max.

8.35 A 

Power consumption

1820 W 

Air volume

5500 m³/h 

Fan

Axial fan

Nominal heat load max.

118 kW

Nominal heat output

105.5 kW

Temperature increase ΔT 

1)

75 °C

Oil consumption max.

10.79 l/h

Tank capacity

135 l

Air transportation hose connection 

2)

1 x ø 500 mm, L-max = 6 m

Air transportation hose connection 

2)

1 x ø 400 mm, L-max = 6 m

Chimney connection

ø 150 mm

Thermostat connection

series

Combustion

indirect

Nozzle

2.00-80° W (gal/h)

Sound  pressure  level  (at  distance 
of 1 m)

76 dB (A)

Length

1918 mm

Width

731 mm

Height

1220 mm

Weight 

149 kg

Fuse

16 A

1) 

indicates the temperature increase. ΔT + ambient temperature = exhaust air 

temperature

2) 

optional

Summary of Contents for IDS 100

Page 1: ...IDS 100 EN OPERATION MANUAL OIL HEATER TRT BA IDS 100 HS 003 INT ...

Page 2: ...eating unit for the first time Please store this operating manual and keep it within reach in order to consult it if necessary Please observe all safety instructions and information on use and main tenance contained in this manual This manual should be attached to the device if the latter is made avail able to other persons for use Legend WARNING SYMBOL This symbol is followed by a hazard warning ...

Page 3: ...Do not apply any liquids to the interior of the device If this does happen nevertheless pull out the power cord and have the de vice checked by a specialist workshop Risk of injury Do not insert any objects into the intake and exhaust opening of the device Do not reach into the existing openings Do not leave children or animals unattended near the operating device Do not operate the device in room...

Page 4: ... for people and property The following points are to be observed during installation The device may be operated indoors and in roofed outdoor areas The device must be installed in a stable position and placed on a fireproof surface The device must be installed near a chimney or external wall The device must be connected to a properly secured mains socket The installation room of the device must be...

Page 5: ...e to a properly secured mains socket 230 V 50 Hz 10 A On construction sites a residual current circuit breaker must be connected upstream of the mains socket according to VDE 0100 0105 The oil heating unit is now ready for operation Use the device according to the functions described in chapter 12 Functions and operation 11 Exhaust system Before planning the installation of the exhaust system the ...

Page 6: ...noz zle may be insufficient This will cause the flame control system to be activated and the device will be blocked Wait for approx 1 minute Press and hold the reset button for at least 5 seconds Switch on the device If the device is still not starting up Make sure that there is enough heating oil in the tank Press the reset button In order to determine the cause of the fault see the chapters Safe...

Page 7: ... a wet cloth The painted and plastic surfaces may not be scoured Do not use any solvent based cleaning agents 15 Disposal The heating oil must be drained from the tank of the oil heating unit and collected Oil heating unit Electronic equipment may not be disposed of in the domestic waste but must be correctly disposed of in accordance with the EUROPEAN PARLIA MENT directive 2002 96 EC of 27th Janu...

Page 8: ...ustomer service and have the device cleaned and heating oil residues removed from the combustion chamber Photoelectric cell defective Have the photoelectric cell replaced by the cus tomer service flashing red light or flashing red green light Motor winding interrupted or blown Have the motor replaced by the customer service Motor bearing blocked Have the motor bearing replaced by the customer serv...

Page 9: ...s Have the position of the air setting ring checked by the customer service Have the support disc of the burner cleaned by the customer service Supply of combustion air too high Have the position of the air setting ring checked by the customer service used heating oil contami nated and or containing water Replace used heating oil with clean heating oil Clean the heating oil filter air has entered ...

Page 10: ...ty thermostat FUA Fuse LI 2 Overheating protection thermostat L1 RV Selector switch EV 1 Solenoid valve I stage FA Air regulator EV 2 Solenoid valve II stage IT Ignition transformer LF RFI filter RF Heated filter optional DV Change over switch power stage high low TF Plug for heated filter TD Transformer Setting of the air setting ring A Type IDS 100 Parameter Value Setting of air setting ring A 1...

Page 11: ......

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...