background image

Operating manual – IDS 100

EN

B-1

Table of Contents

1.  Notes on how to use the manual.............................................. A-1

Legend  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1

2.  Scope of delivery ..................................................................... A-1
3.  Guarantee provisions ............................................................... A-1
4.  General safety instructions ...................................................... A-2
5.  Function and product characteristics ....................................... A-2
6.  Technical data ......................................................................... A-2

Fuels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3

7.   Proper and improper use ......................................................... A-3

Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Improper use   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3

8.  Installation conditions .............................................................. A-3
9.  Description of device ............................................................... A-3

Oil heating unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3

10.  Installation and commissioning ................................................ A-4
11.  Exhaust system ....................................................................... A-4

Chimney duct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Wall duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

12.  Functions and operation .......................................................... A-4

Switching on the oil heating unit  . . . . . . . . . . . . . . . . . . . . A-4
Switching off the oil heating unit . . . . . . . . . . . . . . . . . . . . A-5
Resuming operation after a failure   . . . . . . . . . . . . . . . . . . A-5
Safety equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5

13.  Transport ................................................................................. A-6
14.  Care and maintenance ............................................................. A-6

Cleaning after every 50 operating hours  . . . . . . . . . . . . . . A-6
Cleaning the oil heating unit . . . . . . . . . . . . . . . . . . . . . . . . A-6

15.  Disposal .................................................................................. A-6

Oil heating unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6
Heating oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6
Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6

16.  Service and repair ................................................................... A-6
17.  Troubleshooting ....................................................................... A-6
18.  Appendix ................................................................................. A-9

Circuit diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
Setting of the air setting ring  . . . . . . . . . . . . . . . . . . . . . . . A-9

1. Notes on how to use the manual

This operating manual contains all important information required for a 
safe commissioning and use of your oil heating unit.
It provides you with support for operating the device and remedying pos-
sible  problems  as  well  as  with  information  on  disposal  and  customer 
service.
Please read this manual thoroughly and completely before using the oil 
heating unit for the first time. 
Please store this operating manual and keep it within reach in order to 
consult it if necessary. 
Please observe all safety instructions and information on use and main-
tenance contained in this manual. 
This manual should be attached to the device if the latter is made avail-
able to other persons for use.

Legend

WARNING  SYMBOL. This  symbol  is  followed  by  a 
hazard warning which contains instructions whose 
non-compliance may cause serious injuries and/or 
death and/or property damage. 

Additional information which might be helpful when 
using the device. 

2. Scope of delivery

The scope of delivery of the oil heating unit includes: 

T

RT

-BA-IDS1

0

0

-RE

-00

1

-INT

IDS 100

1

2

4

3

9

17

10

11

16

15

14

13

12

6

7

5

8

1  Operating manual 

10  Wheel 2x

2  Assembly instruction manual  11  Locking pin 2x
3  Oil heating unit ISD 100 

12  Spacer ring 2x

4  Chimney connection 150 mm  13  Hexagon nut 4x
5  Handle 

14  Hexagon screw 4x

6  Support 

15  Screw 4x

7  Hexagon nut 4x 

16  Outlet cone

8  Hexagon screw 4x 

17  Assembly tools

9  Support bracket for axis

3. Guarantee provisions

The  warranty  period  granted  for  the  oil  heating  unit  IDS  100  shall  be 
12 months.
Any damage to the device resulting from non-compliance with the in-
structions contained in this manual shall be excluded from the guarantee.
The  manufacturer  shall  assume  no  liability  for  damages  to  the  device 
and/or its accessories that are caused by unauthorised modifications.
For  any  further  terms  of  guarantee,  please  refer  to  the  General Terms 
and Conditions (GTC), which are available on our website: www.trotec.de. 

Summary of Contents for IDS 100

Page 1: ...IDS 100 EN OPERATION MANUAL OIL HEATER TRT BA IDS 100 HS 003 INT ...

Page 2: ...eating unit for the first time Please store this operating manual and keep it within reach in order to consult it if necessary Please observe all safety instructions and information on use and main tenance contained in this manual This manual should be attached to the device if the latter is made avail able to other persons for use Legend WARNING SYMBOL This symbol is followed by a hazard warning ...

Page 3: ...Do not apply any liquids to the interior of the device If this does happen nevertheless pull out the power cord and have the de vice checked by a specialist workshop Risk of injury Do not insert any objects into the intake and exhaust opening of the device Do not reach into the existing openings Do not leave children or animals unattended near the operating device Do not operate the device in room...

Page 4: ... for people and property The following points are to be observed during installation The device may be operated indoors and in roofed outdoor areas The device must be installed in a stable position and placed on a fireproof surface The device must be installed near a chimney or external wall The device must be connected to a properly secured mains socket The installation room of the device must be...

Page 5: ...e to a properly secured mains socket 230 V 50 Hz 10 A On construction sites a residual current circuit breaker must be connected upstream of the mains socket according to VDE 0100 0105 The oil heating unit is now ready for operation Use the device according to the functions described in chapter 12 Functions and operation 11 Exhaust system Before planning the installation of the exhaust system the ...

Page 6: ...noz zle may be insufficient This will cause the flame control system to be activated and the device will be blocked Wait for approx 1 minute Press and hold the reset button for at least 5 seconds Switch on the device If the device is still not starting up Make sure that there is enough heating oil in the tank Press the reset button In order to determine the cause of the fault see the chapters Safe...

Page 7: ... a wet cloth The painted and plastic surfaces may not be scoured Do not use any solvent based cleaning agents 15 Disposal The heating oil must be drained from the tank of the oil heating unit and collected Oil heating unit Electronic equipment may not be disposed of in the domestic waste but must be correctly disposed of in accordance with the EUROPEAN PARLIA MENT directive 2002 96 EC of 27th Janu...

Page 8: ...ustomer service and have the device cleaned and heating oil residues removed from the combustion chamber Photoelectric cell defective Have the photoelectric cell replaced by the cus tomer service flashing red light or flashing red green light Motor winding interrupted or blown Have the motor replaced by the customer service Motor bearing blocked Have the motor bearing replaced by the customer serv...

Page 9: ...s Have the position of the air setting ring checked by the customer service Have the support disc of the burner cleaned by the customer service Supply of combustion air too high Have the position of the air setting ring checked by the customer service used heating oil contami nated and or containing water Replace used heating oil with clean heating oil Clean the heating oil filter air has entered ...

Page 10: ...ty thermostat FUA Fuse LI 2 Overheating protection thermostat L1 RV Selector switch EV 1 Solenoid valve I stage FA Air regulator EV 2 Solenoid valve II stage IT Ignition transformer LF RFI filter RF Heated filter optional DV Change over switch power stage high low TF Plug for heated filter TD Transformer Setting of the air setting ring A Type IDS 100 Parameter Value Setting of air setting ring A 1...

Page 11: ......

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: