background image

Operating manual – IDS 100

EN

B-9

18. Appendix

Circuit diagram

AP  Control unit 

FO  Photoelectric cell

TA  Thermostat connection 

CO  Capacitor 

ST  Indicator lamp 

MV  Fan motor 

FU  Fuse 

MB  Burner motor 

LI 1  Safety thermostat 

FUA  Fuse

LI 2  Overheating protection, thermostat, L1 

RV  Selector switch

EV 1 Solenoid valve I° stage 

FA 

Air regulator

EV 2 Solenoid valve II° stage 

IT 

Ignition transformer

LF  RFI filter 

RF 

Heated filter (optional)

DV  Change-over switch, power stage (high-low) 

TF 

Plug for heated filter

TD  Transformer

Setting of the air setting ring

  A

Type IDS 100

Parameter

Value

Setting of air setting ring

A=1.5

Summary of Contents for IDS 100

Page 1: ...IDS 100 EN OPERATION MANUAL OIL HEATER TRT BA IDS 100 HS 003 INT ...

Page 2: ...eating unit for the first time Please store this operating manual and keep it within reach in order to consult it if necessary Please observe all safety instructions and information on use and main tenance contained in this manual This manual should be attached to the device if the latter is made avail able to other persons for use Legend WARNING SYMBOL This symbol is followed by a hazard warning ...

Page 3: ...Do not apply any liquids to the interior of the device If this does happen nevertheless pull out the power cord and have the de vice checked by a specialist workshop Risk of injury Do not insert any objects into the intake and exhaust opening of the device Do not reach into the existing openings Do not leave children or animals unattended near the operating device Do not operate the device in room...

Page 4: ... for people and property The following points are to be observed during installation The device may be operated indoors and in roofed outdoor areas The device must be installed in a stable position and placed on a fireproof surface The device must be installed near a chimney or external wall The device must be connected to a properly secured mains socket The installation room of the device must be...

Page 5: ...e to a properly secured mains socket 230 V 50 Hz 10 A On construction sites a residual current circuit breaker must be connected upstream of the mains socket according to VDE 0100 0105 The oil heating unit is now ready for operation Use the device according to the functions described in chapter 12 Functions and operation 11 Exhaust system Before planning the installation of the exhaust system the ...

Page 6: ...noz zle may be insufficient This will cause the flame control system to be activated and the device will be blocked Wait for approx 1 minute Press and hold the reset button for at least 5 seconds Switch on the device If the device is still not starting up Make sure that there is enough heating oil in the tank Press the reset button In order to determine the cause of the fault see the chapters Safe...

Page 7: ... a wet cloth The painted and plastic surfaces may not be scoured Do not use any solvent based cleaning agents 15 Disposal The heating oil must be drained from the tank of the oil heating unit and collected Oil heating unit Electronic equipment may not be disposed of in the domestic waste but must be correctly disposed of in accordance with the EUROPEAN PARLIA MENT directive 2002 96 EC of 27th Janu...

Page 8: ...ustomer service and have the device cleaned and heating oil residues removed from the combustion chamber Photoelectric cell defective Have the photoelectric cell replaced by the cus tomer service flashing red light or flashing red green light Motor winding interrupted or blown Have the motor replaced by the customer service Motor bearing blocked Have the motor bearing replaced by the customer serv...

Page 9: ...s Have the position of the air setting ring checked by the customer service Have the support disc of the burner cleaned by the customer service Supply of combustion air too high Have the position of the air setting ring checked by the customer service used heating oil contami nated and or containing water Replace used heating oil with clean heating oil Clean the heating oil filter air has entered ...

Page 10: ...ty thermostat FUA Fuse LI 2 Overheating protection thermostat L1 RV Selector switch EV 1 Solenoid valve I stage FA Air regulator EV 2 Solenoid valve II stage IT Ignition transformer LF RFI filter RF Heated filter optional DV Change over switch power stage high low TF Plug for heated filter TD Transformer Setting of the air setting ring A Type IDS 100 Parameter Value Setting of air setting ring A 1...

Page 11: ......

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: