Operating manual – IDS 100

EN

B-3

Fuels

The following fuels have been approved for use with the oil heating unit 
IDS 100: heating oil EL, diesel

7.  Proper and improper use

Proper use

The oil heating unit IDS 100 has been developed for the generation of hot 
air and may be used indoors and in roofed outdoor areas.
The  device  can  be  used  for  heating  large  rooms  such  as  storerooms, 
workshops,  building  sites,  greenhouses  or  cowsheds.  It  has  been  de-
signed  for  stationary  operation  without  frequently  changing  locations. 
The oil heating unit can be used in conjunction with an air transportation 
hose.
Any application deviating from the above-mentioned use is deemed in-
admissible!

Improper use 

The device may not be installed or operated in potentially inflammable 
and explosive rooms or areas. 
The device may not be used in rooms with an insufficient supply of com-
bustion air. 

8. Installation conditions

When choosing the installation location of the oil heating unit, a number 
of spatial and technical conditions must be taken into account. Any non-
compliance may impair the functioning of the device and/or of the acces-
sories or result in hazardous situations for people and property.
The following points are to be observed during installation: 

  The device may be operated indoors and in roofed outdoor areas.

 The device must be installed in a stable position and placed on
a fireproof surface.

 The device must be installed near a chimney or external wall.

 The  device  must  be  connected  to  a  properly  secured  mains
socket.

 The installation room of the device must be sufficiently ventilated.

 The minimum distance of the intake opening of the device to the
wall must be at least 1 m (see figure).

min. 1 m 

 The  minimum  distance  of  the  device  to  inflammable  materials
must be at least 2 m.

 The intake and exhaust openings must not be covered.

 There may be no walls or large objects near the device.

 

A sufficient number of fire-extinguishing systems must be available.

9. Description of device

The oil heating unit IDS 100 consists of the following components: 

Oil heating unit

1

2 3 4 5

6

7

9

10

12

13

14

11

8

1  Combustion chamber 

8  Heating oil filter

2  Burner 

9  Heating oil circuit

3  Nozzle 

10  Support and handle

4  Pump 

11  Wheel

5  Solenoid valve 

12  Tank

6  Fan motor 

13  Burner motor

7  Fan 

14 Combustion air regulator

Control panel

1

2

3

6

4

5

1  Reset button with indicator lamp 

4  Change-over switch, power stage

2  Selector switch 

(high-low)

(ventilation/heating, thermostat operation)  5  Lamp

3  Thermostat socket 

6  Power supply cable

Summary of Contents for IDS 100

Page 1: ...IDS 100 EN OPERATION MANUAL OIL HEATER TRT BA IDS 100 HS 003 INT ...

Page 2: ...eating unit for the first time Please store this operating manual and keep it within reach in order to consult it if necessary Please observe all safety instructions and information on use and main tenance contained in this manual This manual should be attached to the device if the latter is made avail able to other persons for use Legend WARNING SYMBOL This symbol is followed by a hazard warning ...

Page 3: ...Do not apply any liquids to the interior of the device If this does happen nevertheless pull out the power cord and have the de vice checked by a specialist workshop Risk of injury Do not insert any objects into the intake and exhaust opening of the device Do not reach into the existing openings Do not leave children or animals unattended near the operating device Do not operate the device in room...

Page 4: ... for people and property The following points are to be observed during installation The device may be operated indoors and in roofed outdoor areas The device must be installed in a stable position and placed on a fireproof surface The device must be installed near a chimney or external wall The device must be connected to a properly secured mains socket The installation room of the device must be...

Page 5: ...e to a properly secured mains socket 230 V 50 Hz 10 A On construction sites a residual current circuit breaker must be connected upstream of the mains socket according to VDE 0100 0105 The oil heating unit is now ready for operation Use the device according to the functions described in chapter 12 Functions and operation 11 Exhaust system Before planning the installation of the exhaust system the ...

Page 6: ...noz zle may be insufficient This will cause the flame control system to be activated and the device will be blocked Wait for approx 1 minute Press and hold the reset button for at least 5 seconds Switch on the device If the device is still not starting up Make sure that there is enough heating oil in the tank Press the reset button In order to determine the cause of the fault see the chapters Safe...

Page 7: ... a wet cloth The painted and plastic surfaces may not be scoured Do not use any solvent based cleaning agents 15 Disposal The heating oil must be drained from the tank of the oil heating unit and collected Oil heating unit Electronic equipment may not be disposed of in the domestic waste but must be correctly disposed of in accordance with the EUROPEAN PARLIA MENT directive 2002 96 EC of 27th Janu...

Page 8: ...ustomer service and have the device cleaned and heating oil residues removed from the combustion chamber Photoelectric cell defective Have the photoelectric cell replaced by the cus tomer service flashing red light or flashing red green light Motor winding interrupted or blown Have the motor replaced by the customer service Motor bearing blocked Have the motor bearing replaced by the customer serv...

Page 9: ...s Have the position of the air setting ring checked by the customer service Have the support disc of the burner cleaned by the customer service Supply of combustion air too high Have the position of the air setting ring checked by the customer service used heating oil contami nated and or containing water Replace used heating oil with clean heating oil Clean the heating oil filter air has entered ...

Page 10: ...ty thermostat FUA Fuse LI 2 Overheating protection thermostat L1 RV Selector switch EV 1 Solenoid valve I stage FA Air regulator EV 2 Solenoid valve II stage IT Ignition transformer LF RFI filter RF Heated filter optional DV Change over switch power stage high low TF Plug for heated filter TD Transformer Setting of the air setting ring A Type IDS 100 Parameter Value Setting of air setting ring A 1...

Page 11: ......

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: