air washer AW 20 S

Disassembling the disk

1. Take the disk out of the water tank.
2. Open the lateral screwing with the Easy Kit or with a coin

by turning the cap counter-clockwise.

3. Remove the cap.
4. You can take the disks off the shaft and clean them

individually.

5. After cleaning, slide the disks back on the shaft.
6. Put the cap back on the shaft and fasten the cap by turning

clockwise.

7. Reinsert the disk into the device. Check the disk for

complete movability. If necessary, reposition the
SecoSan

®

 Stick so that the disk can turn freely.

8. Put the upper part back on the device.

Cleaning the pre-filters

Clean the pre-filters regularly, at the latest when heavy soiling is
visible.
Proceed as follows to clean the pre-filters:

ü

The device is switched off and disconnected from the
mains.

1. Slightly press onto the air inlet louvre on both sides of the

device.

ð

The louvres open.

2. Fold out the louvres up to the lock position at 45°.

3. Remove the two pre-filters.
4. Clean the pre-filters under fresh water with a soft cloth.

5. Remove the two louvres by carefully pressing them down.

6. Clean the louvres under fresh water with a soft cloth.

7. Dry the pre-filters and the louvres before refitting them into

the device.

8. Reinsert the louvres into the guides and fold up the louvres

until they lock in place at approx. 45°.

9. Refit the pre-filters into the guide rail in the louvre.
10. Close the louvres with a snap.

Summary of Contents for AW 20 S

Page 1: ...TRT BA AW20S TC2015 32 005 EN AW 20 S EN OPERATING MANUAL AIR WASHER ...

Page 2: ...device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kn...

Page 3: ...ids other than fresh drinking water Do not use the device for removing heavy contaminations from the air Any unauthorised modifications alterations or structural changes to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the operating manual especially the ...

Page 4: ...If the water tank is empty a warning signal will be emitted and the device switches off automatically In sensor controlled automatic operation an intelligent sensor measures the air quality and humidity level A three stage light signal indicates the air quality in the room The relative humidity is also indicated All in all you can select nine different operating modes What is more a plasma generat...

Page 5: ...ckaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create tripping hazards when laying the power cable or ot...

Page 6: ... purification mode is activated 23 Night mode indication Illuminated when night mode is activated 24 Fan min indication The fan runs at minimum speed No Designation Description 25 Humidity level indication Indicates the current room humidity level up to 60 even if the device switches off at 50 airwasher zone comfort zone between 40 and 60 26 Fan med indication The fan runs at medium speed 27 Fan m...

Page 7: ...off the illuminated plasma generator indication 29 goes out Adding water If the water tank indication 17 is illuminated you have to refill water Note After approx one week of operation the water tank should be cleaned before refilling with fresh drinking water Further information on cleaning the water tank can be found in the chapter Maintenance 1 Press the power button 13 ð The device switches of...

Page 8: ...oSan stick Clean the water tank at least once a week and prior to every start up or shutdown ü The device is switched off and disconnected from the mains ü The upper part of the device has already been removed from the device 1 Take the disk out of the water tank 2 If required take the SecoSan stick out of the water tank 3 Discharge the residual water into a drain 4 Clean the inside of the water t...

Page 9: ...ilters Clean the pre filters regularly at the latest when heavy soiling is visible Proceed as follows to clean the pre filters ü The device is switched off and disconnected from the mains 1 Slightly press onto the air inlet louvre on both sides of the device ð The louvres open 2 Fold out the louvres up to the lock position at 45 3 Remove the two pre filters 4 Clean the pre filters under fresh wate...

Page 10: ...lters should be firmly seated in the guide rails 6 Put the upper part back on the device 7 After switching the device back on simultaneously press the operating mode button 19 and the fan stage button 20 for approx 3 s ð The HEPA filter indication 16 is no longer illuminated Cleaning the dust sensor Clean the dust sensor approx every 6 months In very dusty surroundings the dust sensor should be cl...

Page 11: ...or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: