Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Check whether the upper and lower part are properly
connected to one another.

Wait for 10 minutes before restarting the device. 
If the device is not starting, have the electrics checked by
a specialist company or by Trotec.

Water is leaking:

Check whether the device is set up in a stable and upright
position.

Check the device for leaks.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Cleaning the water tank and replacing the (optional)
SecoSan® stick

Clean the water tank at least once a week and prior to every
start-up or shutdown.

ü

The device is switched off and disconnected from the
mains.

ü

The upper part of the device has already been removed
from the device.

1. Take the disk out of the water tank.
2. If required, take the SecoSan

®

 stick out of the water tank.

3. Discharge the residual water into a drain.
4. Clean the inside of the water tank with a mild detergent.
5. Thoroughly rinse the water tank with clear water.
6. Dry the inside of the tank with a lint-free cloth.
7. If you want to continue using the SecoSan

®

 stick, rinse it

thoroughly with clear water.

ð

The SecoSan

®

 stick should be exchanged approx. every

6 months. The LED for the SecoSan

®

 stick lights up

when an exchange is required. After replacement
dispose of the SecoSan

®

 stick properly.

8. Insert the (new) SecoSan

®

 stick in a corner of the water

tank. Make sure not to block the rotating disk.

9. Refit the disk. Check the disk for complete movability. 

If necessary, reposition the SecoSan

®

 stick so that the disk

can turn freely.

10. Fill the water tank with fresh drinking water.
11. Put the upper part back on the device.

If you replaced the SecoSan

®

 stick, the 

SecoSan

®

 stick

indication (15) needs to be reset after having switched the
device back on:

1. Simultaneously press and hold the buttons 

power

 (13) and

plasma generator

 (30) for approx. 3 s.

ð

The illuminated 

SecoSan

®

 stick

 indication (15) goes out.

Cleaning the disk

ü

The device is switched off and disconnected from the
mains.

ü

The upper part of the device has already been removed
from the device.

1. In case of slight soiling, insert the Easy Kit between two of

the disks and move it back and forth.

2. In case of heavy soiling, you can disassemble the disk into

its individual components and clean them thoroughly:

Summary of Contents for AW 20 S

Page 1: ...TRT BA AW20S TC2015 32 005 EN AW 20 S EN OPERATING MANUAL AIR WASHER ...

Page 2: ...device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kn...

Page 3: ...ids other than fresh drinking water Do not use the device for removing heavy contaminations from the air Any unauthorised modifications alterations or structural changes to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the operating manual especially the ...

Page 4: ...If the water tank is empty a warning signal will be emitted and the device switches off automatically In sensor controlled automatic operation an intelligent sensor measures the air quality and humidity level A three stage light signal indicates the air quality in the room The relative humidity is also indicated All in all you can select nine different operating modes What is more a plasma generat...

Page 5: ...ckaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create tripping hazards when laying the power cable or ot...

Page 6: ... purification mode is activated 23 Night mode indication Illuminated when night mode is activated 24 Fan min indication The fan runs at minimum speed No Designation Description 25 Humidity level indication Indicates the current room humidity level up to 60 even if the device switches off at 50 airwasher zone comfort zone between 40 and 60 26 Fan med indication The fan runs at medium speed 27 Fan m...

Page 7: ...off the illuminated plasma generator indication 29 goes out Adding water If the water tank indication 17 is illuminated you have to refill water Note After approx one week of operation the water tank should be cleaned before refilling with fresh drinking water Further information on cleaning the water tank can be found in the chapter Maintenance 1 Press the power button 13 ð The device switches of...

Page 8: ...oSan stick Clean the water tank at least once a week and prior to every start up or shutdown ü The device is switched off and disconnected from the mains ü The upper part of the device has already been removed from the device 1 Take the disk out of the water tank 2 If required take the SecoSan stick out of the water tank 3 Discharge the residual water into a drain 4 Clean the inside of the water t...

Page 9: ...ilters Clean the pre filters regularly at the latest when heavy soiling is visible Proceed as follows to clean the pre filters ü The device is switched off and disconnected from the mains 1 Slightly press onto the air inlet louvre on both sides of the device ð The louvres open 2 Fold out the louvres up to the lock position at 45 3 Remove the two pre filters 4 Clean the pre filters under fresh wate...

Page 10: ...lters should be firmly seated in the guide rails 6 Put the upper part back on the device 7 After switching the device back on simultaneously press the operating mode button 19 and the fan stage button 20 for approx 3 s ð The HEPA filter indication 16 is no longer illuminated Cleaning the dust sensor Clean the dust sensor approx every 6 months In very dusty surroundings the dust sensor should be cl...

Page 11: ...or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: