background image

EN

7

air washer AW 20 S

Setting the fan stage

The following table shows an overview of the fan stages:

Operating
mode

Description

Indication

Auto

Fan speed control depending on room
humidity.
When reaching a humidity level of
50 %, the device stops. It continues
to operate as soon as the measured
humidity level falls below 50 %.

Night mode The device runs in night mode. The

LED illumination of the control panel
is dimmed. The fan runs at the lowest
speed.
When reaching a humidity level of
50 %, the device stops. It continues
to operate as soon as the measured
humidity level falls below 50 %.

Fan max

The fan runs at the highest speed,
regardless of the room humidity.

Fan med

The fan runs at medium speed,
regardless of the room humidity.

Fan min

The fan runs at the lowest speed,
regardless of the room humidity.

1. Press the 

fan stage

 selection button (20) until the desired

fan stage is set.

ð

The corresponding indication is illuminated.

Switching the plasma generator on or off

The plasma generator can be switched on or off as needed.

1. Press the 

plasma generator 

button (30) to switch the

plasma generator on or off.

ð

If the plasma generator is switched on, the 

plasma

generator

 indication (29) is illuminated.

ð

If the plasma generator is switched off, the illuminated

plasma generator

 indication (29) goes out.

Adding water

If the 

water tank

 indication (17) is illuminated, you have to refill

water.

Note:

 

After approx. one week of operation, the water tank should be
cleaned before refilling with fresh drinking water. Further
information on cleaning the water tank can be found in the
chapter Maintenance.

1. Press the 

power

 button (13).

ð

The device switches off.

2. Remove the mains plug from the mains socket.
3. Remove the upper part from the water tank.
4. Fill the water tank with fresh drinking water.

ð

The filling level should be below the filling level line in
the water tank.

5. Check whether the (optional) SecoSan

®

 stick is correctly

positioned inside the water tank.

6. Place the upper part onto the water tank.

ð

The display on the upper part and the logo on the lower
part should point in the same direction.

7. Check whether the upper and lower part are properly

interconnected as otherwise the device cannot be
switched on.

8. Plug the mains plug into a sufficiently fused mains socket.
9. Press the 

power

 button (13).

ð

The device switches back on.

Shutdown

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Empty and clean the water tank.

Remove the SecoSan

®

 stick, if necessary.

Clean the upper louvres according to the Maintenance
chapter.

Store the device according to the Storage chapter.

Available accessories

Designation

Article number

SecoSan

®

 Stick 10

6.100.004.110

Summary of Contents for AW 20 S

Page 1: ...TRT BA AW20S TC2015 32 005 EN AW 20 S EN OPERATING MANUAL AIR WASHER ...

Page 2: ...device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kn...

Page 3: ...ids other than fresh drinking water Do not use the device for removing heavy contaminations from the air Any unauthorised modifications alterations or structural changes to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the operating manual especially the ...

Page 4: ...If the water tank is empty a warning signal will be emitted and the device switches off automatically In sensor controlled automatic operation an intelligent sensor measures the air quality and humidity level A three stage light signal indicates the air quality in the room The relative humidity is also indicated All in all you can select nine different operating modes What is more a plasma generat...

Page 5: ...ckaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create tripping hazards when laying the power cable or ot...

Page 6: ... purification mode is activated 23 Night mode indication Illuminated when night mode is activated 24 Fan min indication The fan runs at minimum speed No Designation Description 25 Humidity level indication Indicates the current room humidity level up to 60 even if the device switches off at 50 airwasher zone comfort zone between 40 and 60 26 Fan med indication The fan runs at medium speed 27 Fan m...

Page 7: ...off the illuminated plasma generator indication 29 goes out Adding water If the water tank indication 17 is illuminated you have to refill water Note After approx one week of operation the water tank should be cleaned before refilling with fresh drinking water Further information on cleaning the water tank can be found in the chapter Maintenance 1 Press the power button 13 ð The device switches of...

Page 8: ...oSan stick Clean the water tank at least once a week and prior to every start up or shutdown ü The device is switched off and disconnected from the mains ü The upper part of the device has already been removed from the device 1 Take the disk out of the water tank 2 If required take the SecoSan stick out of the water tank 3 Discharge the residual water into a drain 4 Clean the inside of the water t...

Page 9: ...ilters Clean the pre filters regularly at the latest when heavy soiling is visible Proceed as follows to clean the pre filters ü The device is switched off and disconnected from the mains 1 Slightly press onto the air inlet louvre on both sides of the device ð The louvres open 2 Fold out the louvres up to the lock position at 45 3 Remove the two pre filters 4 Clean the pre filters under fresh wate...

Page 10: ...lters should be firmly seated in the guide rails 6 Put the upper part back on the device 7 After switching the device back on simultaneously press the operating mode button 19 and the fan stage button 20 for approx 3 s ð The HEPA filter indication 16 is no longer illuminated Cleaning the dust sensor Clean the dust sensor approx every 6 months In very dusty surroundings the dust sensor should be cl...

Page 11: ...or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: