Setting the fan stage
The following table shows an overview of the fan stages:
Operating
mode
Description
Indication
Auto
Fan speed control depending on room
humidity.
When reaching a humidity level of
50 %, the device stops. It continues
to operate as soon as the measured
humidity level falls below 50 %.
Night mode The device runs in night mode. The
LED illumination of the control panel
is dimmed. The fan runs at the lowest
speed.
When reaching a humidity level of
50 %, the device stops. It continues
to operate as soon as the measured
humidity level falls below 50 %.
Fan max
The fan runs at the highest speed,
regardless of the room humidity.
Fan med
The fan runs at medium speed,
regardless of the room humidity.
Fan min
The fan runs at the lowest speed,
regardless of the room humidity.
1. Press the
fan stage
selection button (20) until the desired
fan stage is set.
ð
The corresponding indication is illuminated.
Switching the plasma generator on or off
The plasma generator can be switched on or off as needed.
1. Press the
plasma generator
button (30) to switch the
plasma generator on or off.
ð
If the plasma generator is switched on, the
plasma
generator
indication (29) is illuminated.
ð
If the plasma generator is switched off, the illuminated
plasma generator
indication (29) goes out.
Adding water
If the
water tank
indication (17) is illuminated, you have to refill
water.
Note:
After approx. one week of operation, the water tank should be
cleaned before refilling with fresh drinking water. Further
information on cleaning the water tank can be found in the
chapter Maintenance.
1. Press the
power
button (13).
ð
The device switches off.
2. Remove the mains plug from the mains socket.
3. Remove the upper part from the water tank.
4. Fill the water tank with fresh drinking water.
ð
The filling level should be below the filling level line in
the water tank.
5. Check whether the (optional) SecoSan
®
stick is correctly
positioned inside the water tank.
6. Place the upper part onto the water tank.
ð
The display on the upper part and the logo on the lower
part should point in the same direction.
7. Check whether the upper and lower part are properly
interconnected as otherwise the device cannot be
switched on.
8. Plug the mains plug into a sufficiently fused mains socket.
9. Press the
power
button (13).
ð
The device switches back on.
Shutdown
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Empty and clean the water tank.
•
Remove the SecoSan
®
stick, if necessary.
•
Clean the upper louvres according to the Maintenance
chapter.
•
Store the device according to the Storage chapter.
Available accessories
Designation
Article number
SecoSan
®
Stick 10
6.100.004.110