- - XM464-V1.2-NR
18
20-29
Color change to any position
30-39
Color&Gobo change to any position
40-59
No function
60-79
No function
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93
Gobo motor reset
94-96
No function
97-99
Other motor reset
100-119
Internal program 1
120-139
Internal program 2
140-159
Internal program 3
160-179
Internal program 4
180-199
Internal program 5
200-219
Internal program 6
220-239
Internal program 7
240-255
Auto program by music
13
Pan Fine 16bit
0-255
Fine control of Pan movement
14
Tilt Fine 16bit
0-255
Fine control of Tilt movement
ERROR MESSAGE
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is XX” while
there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 5, 6 who has the testing sensor
for positioning. For example, when the display shows “02 Er”, it means there is some error in channel 2. If
there are some errors on channel 1, channel 2, channel 3 at the same time, you may see the error message “01
Er”, “02 Er”, “03 Er” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture
remain error message after performing reset more than 2 times, only the channels which have errors can not
work properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is
not allowed.
01Er:
(Color Wheel error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on
the main PCB). The head is not located in the default position after the reset.
02Er:
(Rotating gobos error) This message will appear after the reset of the fixture and if the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on
the main PCB). The rotating gobo is not located in the default position after the reset.
03Er:
(Gobo rotating error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The zoom is not located in the default position after the reset.
05Er:
(PAN Movement error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color wheel is not located in the default position after the reset.
06Er:
(TILT Movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing