background image

CureSaver 2

5

420825 rev 2

2.  Field of application 

 

The CureSaver 2 is used to accelerate the drying of 
putty, filler, base and top coats. This applies to both 
waterbased and solvent-based products. Its site of use 
is the preparation area and finishing area. Within the 
automotive industry and vehicle maintenance sectors, 
it is used to dry small areas and cure materials before 
polishing.

3. Product 

description

 

The easily manoeuvrable CureSaver 2 is equipped with 
a compact cassette. The cassette is equipped with 3 IR 
lamps with aluminium reflectors and a ventilator. The 
design, combined with a gas spring, makes cassette 
adjustment simple. The IR lamps and reflectors are 
protected against mechanical damage with a mesh. The 
control unit enables flash off (50% heat applying) and 
full bake (100%  

heat applying). The time can be 

set individually for each status.

3.1 Particular 

advantages

3.1.1 Higher quality

 

Using the mobile dryer when you dry putty also 
improves the quality of the top coat. The high surface 
temperature and curing from the inside outwards drive 
all solvents and other reaction products from the coated 
material.

3.1.2  Short drying times

 

 Putty 

 

3 -5 min.

 

 Filler 

 

5 - 10 min.

 

 Primer 

 

8 - 12 min.

 

 Water-base 4 - 6 min.

 

 Base coat   

4 - 8 min.

 

 Top coat   

8 - 12 min.

 

 Clear varnish 

8 - 12 min. 

 

 

3.1.3  Low energy consumption

Electrical energy is used efficiently through short-wave 
technology and aluminium coated reflectors. Surfaces 
are subjected to targeted irradiation. The air is not 
heated.

3.1.4 Good maneuverability

 

The units low weight and high reach makes the ma-
chines very competitive, versatile and easy to use.

3.2 Technical 

data

 

 Electrical diagram, see chapter 11

 

 For machine reach and dimensions, see last page.

English

4.  Instruction to the owner

 

The owner of the mobile dryer must produce clear operat-
ing instructions, adapted to local site conditions, and 
make these available to all users.

 

Mobile dryer users must adhere to these operating 
instructions. This appliance is not intended for use by 
persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person 
responsible for their safety. Children should be super-
vised to ensure that they do not play with the appliance. 
Dispose of spent items at the nearest environmental 
protection facility for recycling.

5. Hazards

 

Fire and explosion

 

To reduce the risk of explosion, do not use in paint 

spraybooths or within 5 m/16 feet of paint spraying 
operations. 

Do not store, prepare or use solvent-containing materi-
als within a 5 m/16 feet radius of the mobile dryer. 
Flammable materials should not be placed close to a 
drying device in use.  If you have a distance less than 
60 cm/2 feet to the object the temperature might raise 
quickly and the risk for fi re increases. Never direct the 
cassette towards highly combustible materials.

 Electrical 

equipment

 

The mobile dryer is operated by highly dangerous electri-

cal voltage.

 

Accessing electrical equipment

 

Before accessing live parts, remove the main connec-
tor from the wall socket. Only professional electricians 
may have direct access into the electrical equipment. 
If the supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

 WARNING!

 

Intensive heat radiation. Hands, face and other parts of 
the body should be exposed as little as possible to the 
heat radiation.

Rated Voltage 

220V - 240 V, 50/60Hz

  

 

Single  Phase

Rated power  

3 emitters, full power 3000 W

Heating elements 

3 quartz, tungsten filament,

  

 

InfraRed  emitters

Fuse* 

16 A slow, type C (UK 13A) (NA 20 A)

Drying surfaces on 

1,0 m x 0,9 m (width x height)

black sheet metal
Dimensions 

See last page

Weight 46 

kg

Noice level 

Less than 70 dB (A)

Max ambient tempera-
ture during operation 

40

o

 Celsius

Max ambient tempera-
ture during storage 
and transportation 

70

o

 Celsius

* The dryer must be supplied by recommended fuse.

Summary of Contents for CureSaver 2

Page 1: ...ration and Spares Manual Montage Gebrauchs Ersatzteilanweisung Manuel d assemblage d utilisation et pi ces de rechange Monterings bruksanvisning och reservdelsmanual Manuale di funzionamento assemblag...

Page 2: ...ersuchplan 17 9 Ersatzteile 18 10 Konformit tserkl rung 20 11 Elektrische Schaltpl ne 23 INNEH LLSF RTECKNING 1 Monteringsanvisning 3 2 Anv ndningsomr de 11 3 Produktbeskrivning 11 3 1 S rskilda f rde...

Page 3: ...black M12 4x berwurfmutter Cache crou noir T cklock f r mutter Dado per raccordi Tapa de la tuerca HCB 8x30 2x Spacer gas strut 2 5 mm 4x Zwischenst ck f r Gasdruckfeder rondelle distans distanziale...

Page 4: ...ique Plastbricka Guarnizione di plastica Arandela de pl stico MRX M5x12 fz 2x Washer neoprene 2x Neopren scheibe Rondelle souple Neoprenbricka Guarnizione ad anello di neoprene Arandela neopreno M10 1...

Page 5: ...yer users must adhere to these operating instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience an...

Page 6: ...e metal clips FLASH OFF LAMP illuminates when the machine is running at half power FLASH OFF TIMER controls the duration of half power 0 30 min FULL BAKE LAMP illuminates when the machine is running a...

Page 7: ...lichen Gegebenhei ten angepasste Betriebs anweisung auslegen die dem jeweiligen Anwender zug nglich sein muss DieAnwender des Mobiltrockners m ssen sich an diese Betrieb sanweisung halten Dieses Ger t...

Page 8: ...tennuten dr cken 5 Die Metallklips wieder einsetzen FLASH OFF LICHT leuchtet wenn das Ger t in der halbe Leistung arbeitet FLASH OFF TIMER reguliert die Dauer der halbe Leistung 0 30 Minuten FULL BAK...

Page 9: ...eur Les utilisateurs du s cheur mobile doivent imp rativement se conformer ces instructions Cet appareil n est pas destin tre utilis par des personnes y compris des enfants qui ont des capacit s physi...

Page 10: ...olvatation flash off T moin rouge de cuisson allum quand l appareil full bake est en fonction cuisson full bake Minuterie de cuisson contr le la dur e de full bake 0 30 minutes de la cuisson full bake...

Page 11: ...ruktion som r allm nt f rst elig och anpassad till f rh llandena p platsen Instruktionen m ste alltid vara tillg nglig f r dem som anv nder mobiltorken De som anv nder mobiltorken m ste f lja denna br...

Page 12: ...nen g r p halveffekt FLASH OFF Tidur styr hur l nge maskinen g r p halv effekt 0 30min FULL EFFKT Lampa lyser n r maskinen g r p hel effekt FULL EFFEKT Tidur styr hur l nge maskinen g r p full effekt...

Page 13: ...ali facilmente raggiungibile dagli utenti Gli operatori dell essiccatore mobile devono attenersi alle istruzioni per l uso Questo apparecchio non destinato all uso da parte di persone compresi i bambi...

Page 14: ...ella plafoniera 5 Rimettere le clip metalliche LUCE FLASH OFF Si accende quando l apperacchio lavora a met potenza FLASH OFF TIMER controlla il periodo di met potenza 0 30 min FULL BAKE LUCE Si accned...

Page 15: ...son conocidas por todos los usuarios posibles Los usuarios del secador m vil deben ajus tarse a las instrucciones de manipulaci n Este aparato no debe ser usado por personas incluidos ni os con capac...

Page 16: ...s met licos L mpara del Flash off se ilumina cuando la evapo raci n maquina est funcion ando a la mitad de potencia Temporizador del Flash off controla la duraci n de esa evaporaci n mitad de potencia...

Page 17: ...ori di spillo Pezzo troppo vicino all appa recchio Insufficiente tempo del flash off La vernice ha il solvente veloce Allontanare il pezzo dall ap parecchio Prolungare il tempo del flash off Usare un...

Page 18: ...29 30 SCA 2 Scale Drawn by STYRENH CONTROL U Certified by MF Approved by Ejo 1 2 Position Art no Description 1 713791 Front plate control unit fabrication 2 420785 Side extrusion Trisk 3 420764 Top pl...

Page 19: ...ower 11 421038 Arm upper 7 9 420819 Gas Strut Assembly 1 5 6 7 8 9 10 11 2 3 4 Position Art no Description 1 410272 Label small Trisk 2 421008 U channel 3 420746 Spacer 4 420730 Cross member CPL 5 711...

Page 20: ...es AB Mats Jonsson Development and Production Director and authorized representative 10 EG Konformit tserkl rung Nach dem Zeugnis von Testinstituten und nach der Maschinenrichtlinie sind die Produkte...

Page 21: ...ective basse tension 2004 108 EC Compatibilit lectromagn tique V nersborg 2010 01 21 Hedson Technologies AB Mats Jonsson Directeur du d partement de d veloppement et de production et repr sentant agr...

Page 22: ...ersborg 2010 01 21 Hedson Technologies AB Mats Jonsson Responsabile di Sviluppo e Produzione e rappresentante autorizzato 10 EC Declaraci n de conformidad De acuerdo a los institutos de prueba y a la...

Page 23: ...CureSaver 2 23 420825 rev 2 11 Electrical diagram Elektrische Schalpplan Sch ma de cablage lectrique Elschema Schemi elettrici Diagrama el ctrico 1 7 6 2 7 8 9 4 0 0 a 1 3 3 8 8 3 0 a 0 a 5...

Page 24: ...ureSaver 2 24 420825 rev 2 HEDSON TECHNOLOGIES AB Box 1530 SE 462 28 V NERSBORG Sweden Tel 46 521 281000 Fax 46 521 66909 www hedson se 157 5 cm 10 5 cm 118 5 cm 14 cm 150 cm 193 cm 215 cm 245 cm 46 k...

Reviews: