III.
SERVICE: Removal and replacement of the HEPA filter.
WARNING!
Disconnect the unit from the electrical power source before attempting any service.
Step 1.
To gain access to the HEPA filter, remove the ceiling panel next to the unit, if
applicable.
Step 2.
Remove unit from ceiling.
Step 3.
Remove the 10 screws holding the HEPA filter to the lid assembly.
Step 4.
Lift the lid assembly off the HEPA filter and discard the HEPA filter (see Figure
4) as per requirements of the applicable regulations.
Note:
Before replacing with a new HEPA filter, carefully inspect the new filter
for any visible damage.
Step 5.
Also inspect the gasketing in the “tee” bar to insure a tight seal. Replace as
necessary.
Step 6.
Replace with the new HEPA filter and assemble by reversing the above steps.
ELIMINATOR OWNER’S MANUAL