58
AT.654254.050 ver.1.0
Troubleshooting manual
Power input/output compartment
Reference marks in VSD AK06-
RD 300….420 Amps with output frequency up to
200 Hz.
VSD AK06-
RD 300….420 A
mps with output frequency up to 200 Hz
1.
Slinging ears.
2.
WYE - point connection terminal
3.
RisS
–
measuring of motor winding resistance
4.
OutM
–
measuring VSD output parameters
5.
Output power connections
6.
Cabinet doors control
7.
Current transformers
8.
Gro
unded «Neutral»
connection terminal
9.
Sinwave filter capacitors
10.
Grounded «Insulated neutral» connection terminal
11.