TX7410 Operation Manual
45
5.2.2 GPIB interface functions
TX7410 's GPIB functions are listed in the following table.
Code
Function
SH1
Complete Source Handshake capability
AH1
Complete Acceptor Handshake capability
T3
Basic Talker; Talk-Only; unaddressed if MLA; no serial poll
L3
Basic Listener; unaddressed if MTA; no Listen Only
RL1
Remote/Local capability
DC1
Device Clear capability
DT1
Device Trigger capability
C0
No Controller capability
E1
Drivers are open-collector
5.2.3 GPIB addressing
TX7410 's GPIB address is stored in non-volatile memory and can be set to any address
from 0 to 30 by front panel key entry in the System Config page. When TX7410 is shipped
from the factory, the default GPIB address is 8. For more information, refer to “ 4.2.16
GPIB Address”.
5.2.4 GPIB bus function
TX7410 will respond to the following bus commands.
ABORT I/O (IFC)
ABORT I/O (IFC control line TRUE) halts all bus activity and deselects TX7410 .
DEVICE CLEAR (SDC or DCL)
This command can be used with an address to clear a particular device (SDC : selected
device clear) or used without an address (DCL : clears all devices). The Input buffer is
cleared, output data buffer is cleared and bit 4 (MAV bit) of the status byte is set to “0”,
when TX7510 receives this command.
LOCAL (GTL)
LOCAL returns control of a listening device to front panel control.
REMOTE (RMT)
REMOTE sets TX7410 to the remote mode. When this command is sent, front panel with
the exception of LOCAL softkey will be disabled.
TRIGGER (GET)
It enables TX7410 to the TRIGGER bus command. This command may be sent to a
selected device or to all devices addressed as listeners on the GPIB bus. TX7410 must first
be addressed as a listener, second the trigger mode is set to the BUS trigger mode before
the trigger message is sent. This command is equal to the SCPI command TRIG+FETCh?
or the common command *TRG.