TX7410 Operation Manual
30
Figure 4-22 Limit setup of secondary parameter
4.2.15 File operation function
Perform the following steps to enter file operation page:
1.
At test status, press SHIFT key, and “SHIFT” at left corner is on.
2.
Press FILE key to enter file operation page, and the instrument first displays
currently-used file No., (if no file is loaded, the default setup of file No. 0 displays), as
shown in 4-23.
Figure 4-23 File operation page
File can be saved, loaded or erased.
1) SAVE
This operation saves the current setups to appointed file No. Perform the following steps to
save file:
a) Select “SAVE” at file operation page through
【
▲
】
or
【
▼
】
key, as shown in Figure4-25.
b) Press
【
▲
】
or
【
▼
】
key to select appointed file No. from 0-9. Displayed “Y” means the
file has existed, and it will be covered at the time of saving, and “N” means the file doesn’t
exist.
c) Press
【
ENTER
】
key to perform the saving operation, and “WAIT” displays.
d) Press
【
ESC
】
to exit.
2) LOAD
The operation loads setups of appointed file. Perform the following steps to load file.
a) Select “LOAD” at file operation page through
【
▲
】
or
【
▼
】
key, as shown in Figure4-24.
b) Press
【
▲
】
or
【
▼
】
key to select loading file No. Displayed “Y” means the file has existed,
and it will be loaded, and “N” means the file doesn’t exist.
c) Press
【
ENTER
】
key to perform the loading operation, and it automatically exits back to
measurement page after loading completes.
d) Press
【
ESC
】
to exit.