Revision C August 2014
www.trinityhighway.com
27
All rights in copyright reserved
10) Attach End Cap
Using 5/8” x 3 1/2" G5 hex bolt, 5/8” hex nut, and 5/8” lock washer, attach the End Cap to
the front of the first Monorail segment (see Figure 38).
Figure 37
Proper spacing between Bays
(Wide System shown)
Figure 38
Monorail End Cap Attachment