Revision C August 2014
www.trinityhighway.com
25
All rights in copyright reserved
Starting at the last bay, attach left and right Fender Panel (see Figure 35). Attach the Hinge
Plate at the front of the Fender Panels to the Diaphragm in front using three 5/8” hex bolts,
nuts and washers.
Attach Mushroom Washer Assembly as shown in Figures 34 and 35 but do not torque at this
time.
Be sure Mushroom Washer lays flat against the Fender Panel as shown in Figure 33.
Standoff on washer must be seated completely through slot.
Warning:
Maximum Fender Panel gap allowed for wide systems: 25 mm
[1.00”] (see Figure 33).
Figure 34
Mushroom Washer Attachment
for Wide Systems
Figure 33
Fender Panel Gap for Wide Systems
DIAPHRAGM
1-1/2” DIE SPRING
5/8” FLATHEAD
SOCKET SCREW
MUSHROOM WASHER
5/8” HEX NUT (SMALL)