Date: 2019.9.24 Doc No: PS-M-0691 Ver. B Page - 23 - of 27
Pressure
Factor
Clamp
+1600 Pa
/-1600 Pa
1.5
150mm
*NOTE: The above-described distance is from the module edge to
the middle of the clamp.
*NOTE: Need two support rails below the PV module to make sure
the mechanical load.
*NOTE: The actual load is + 2400Pa/-2400Pa
72Pcs MODULES( frameless)
Mechanical
Load
Pressure
Safety
Factor
Length
Of The
Clamp
Mounting Direction (The crossbeam is perpendicular to the long
side.)
+3600 Pa
/-1600 Pa
1.5
150mm
*NOTE: The above-described distance is from the module edge to
the middle of the clamp.
*NOTE: Need three support rails below the PV module to make
sure the mechanical load ,
The middle rail of the half-cut design
module assembly needs to avoid the junction box area and move
50mm to the head
*NOTE: The actual load is + 5400Pa/-2400Pa