Date: 2019.9.24 Doc No: PS-M-0691 Ver. B Page - 8 - of 27
72Pcs MODULES(frame)
Mechanical Load Pressure
Safety
Factor
Mounting Direction
(The crossbeam is perpendicular to the long
side.)
+3600 Pa / -1600 Pa
1.5
*NOTE: The above-described distance is from the middle of the
bolts
to the middle of the
bolts
*NOTE: Need two support rails below the PV module to make
sure the Mechanical load.
*NOTE: The actual load is + 5400Pa/-2400Pa
Mechanical Load Pressure
Safety
Factor
Mounting Direction(The beam is parallel to the long side.)
+1600Pa/-1600Pa
1.5
*NOTE: The above-described distance is from the middle of
the
bolts
to the middle of the
bolts
*NOTE: Need two support rails below the PV module to make
sure the Mechanical load.
*NOTE: Standard product with actual load of + 2400Pa/-2400Pa