20
5.6
Gravel specification
Primary backfill specification:
•
Primary backfill material should be free-flowing granular material.
•
Compaction should be by lightweight rollers or vibratory plate. Compact gravel evenly to
ensure proper support for the tank. Ensure the vibrating machine does not come in contact
with the shell of the tank.
•
Install tanks with primary backfill only within the region immediately surrounding the
tanks. This primary backfill must extend a minimum of 250mm outward from the tank, and
directly beneath the tank.
•
Backfill material shall not be frozen or contain lumps of frozen material at any time during
installation.
•
Use of other than specified backfill and bedding materials will void the tank warranty.
The following approved material is suitable for primary backfill:
Rounded pea gravel:
•
Minimum particle size 3mm, maximum 18 mm, compacted to a relative density of >70%.
•
Gravel shall be clean and free flowing, free from large rocks, dirt, sand, roots, organic
materials or debris.
•
Upon screening analysis, the backfill material shall have no more than 5% by weight
passing 2.36 mm sieve.
or
Crushed or processed stone:
•
Minimum particle size 3 mm, maximum 12 mm, compacted to a relative density of >40%
•
Dry Gravel density must be at least 1500 kg/m3. The material should be washed or screened to
remove fine particles.
•
Upon screening analysis, the backfill material shall have no more than 5% by weight passing
2.36 mm sieve.
Pea Gravel
Crushed Stone
Summary of Contents for Novo UK10
Page 4: ...3...
Page 5: ...4...
Page 10: ...9...
Page 11: ...10...
Page 27: ...26 UK18 UK24 Control Panel No 209116...
Page 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Page 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Page 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Page 43: ...42...