11
Two-tank Tricel Novo plants require a stepped installation:
3.3
Pumped Outlet
•
All Tricel Novo tanks are available with a pumped outlet option. The pump is housed in the
final settlement chamber of the plant.
•
A non-return valve installed on the pumped outlet will prevent backflow into the plant.
•
Outlined below is the standard pump specification. Other pump options are available to
customer specifications if required; please contact your Tricel Novo supplier.
•
Min. discharge rate: 60 l/min
•
Continuous duty with 35°C
liquids & fully submerged.
•
Dry motor (class F
insulation).
•
IP68 protection.
•
Single phase 220-240V 50 Hz
2 poles.
•
0.55kW for single phase.
Summary of Contents for Novo UK10
Page 4: ...3...
Page 5: ...4...
Page 10: ...9...
Page 11: ...10...
Page 27: ...26 UK18 UK24 Control Panel No 209116...
Page 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Page 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Page 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Page 43: ...42...