STEP + - STORE
STEP + - STORE
+
Short
Shows supply set point
when responding to call for
heat (Note 1)
c 180
1
DHW reference
set point (Note 2)
68°F - 144°F
(Default Setting
135°F)
1
Supply water temperature
1.170
+
Long
Turn heating on/off
c OFF
0 = Off
2
Return water temperature
2.135
-
Short
Shows domestic hot water
reference set point
(Note 2)
d 134
1 = On
3
Reserved for Future Use
3.-22
-
Long
Turn domestic hot water
on/off
d OFF
2 = Off +
continuous pump
4
Outdoor sensor temp., if
used (Note 5)
4.-22
+ and
MODE
Long
Hold burner in high fire
(Note 3)
H 180
3 = On +
continuous pump
5
Flue gas temperature
5.165
- and
MODE
Long
Hold burner in low fire
(Note 3)
L 180
0 = Off
6
Supply water set point
temperature
6.180
+
and
-
Long
Deactivate forced high or
low firing
O 180
1 = On
STEP
and
MODE
Long
(Note 6)
Activates
CODE MODE
(See Below)
C _ _
2 = Off +
continuous pump
3 = On +
continuous pump
Use of
Keys
Duration
Result
Display
Example
9
Reserved for Future Use
9. 0 0
RESET
Short
Reset or Unlocking
A
Reserved for Future Use
A. -22
MODE
Short
Next Mode (Standby)
StbY
STEP
No Function
STORE
Short
Enter Code
C 88
+
Short
Increase Code
C 89
-
Short
Decrease Code
C 87
+
Continuous Fast Increase Code
C 95
-
Continuous Fast Decrease Code
C 81
1) If outdoor sensor is connected, this temperature is the supply temperature setpoint when the outdoor temperature is 0°F.
2) "Domestic water reference set point" + 45°F = boiler supply set point when boiler is responding to a call for domestic hot water (default = 180°F).
3) Boiler will automatically resume modulation after 15 minutes.
4) Factory default settings are shown in bold.
5) If no outdoor sensor is connected, display reads "4.-22".
6) Depress and hold the
STEP
key and then quickly depress and hold the
MODE
key to activate
CODE MODE
.
CODE MODE
is active when the display shows a 'C' followed by a 2 digit random number.
7) Displays the most recent error code and the boiler status at the time the error occurred.
FIGURE 1.1: EXPANDED MENU TREE
USE
MODE
KEY TO TOGGLE BETWEEN MODES
(Mode returns to Standby from other modes if no key is pressed for 20 min.)
STANDBY MODE
(
StbY
)
INFORMATION MODE
(
INFO
)
PARAMETER MODE
(
PArA
)
5 thru 42
See Table 2.1 for description and
possible setttings
Value
Use of
Keys
Duration
Use of Keys
Possible Settings
(Note 4)
Description
Parameter
N
ot
U
se
d
Display
Example
Result
Display
Example
Heat Zone
Sav
es
new
s
et
ting
to
M
C
BA.
D
is
play
w
ill
Flas
h
w
hen
ST
OR
E
is
releas
ed
indic
at
ing
that
c
hange
ha
s
be
en
m
ad
e
8
4
Supply set point
when responding
to call for heat
68°F - 190°F
(Default Setting
180°F)
Use of Keys
Rate of change in supply
water temperature °F/sec
Rate of change in return
water temperature °F/sec
7. 0 0
8. 0 0
Step
#
Toggle
Bet
w
een
St
eps
1
- A
N
ot
U
se
d
7
Toggle
Bet
w
een
Param
et
ers
2
DHW Zone
3
CODE MODE
(
COdE
)
N
ot
U
se
d
In
cre
as
es
Se
ttin
g
D
ec
re
as
es
S
et
tin
g
86
FIGURE A.1: EXPANDED MENU TREE
Summary of Contents for Triumph series
Page 2: ......
Page 34: ...32 FIGURE 6 23 CONDENSATE PIPING ARRANGEMENT ...
Page 48: ...46 Figure 8 14 Multiple Boiler Piping ...
Page 50: ...Figure 9 1 Wiring Connections Diagram 48 ...
Page 51: ...Figure 9 2 Ladder Diagram 49 ...
Page 69: ...67 PAGE INTENTIONALLY LEFT BLANK ...
Page 71: ...69 ...
Page 72: ...70 ...
Page 73: ...71 ...
Page 75: ...73 ...
Page 76: ...74 ...
Page 78: ...76 ...
Page 79: ...77 ...
Page 82: ...80 ...
Page 83: ...81 155 156 158 157 160 159 ...
Page 84: ...82 161 162 164 163 166 165 ...
Page 85: ...83 167 ...