50xx Easyform-ed0811
¥
50xx EASYFORM
13
S
R
Table 5.1 - Setting mix and pause times
What is your need?
What you should do
How the displays will look
I do not need mix or pause
times
Set both times at zero
Mix and pause lights are off.
The displays show no numbers.
I need only a mix time, no
pause
Set mix time at the desired value.
Mix light is on.
Pause light is off.
The two displays show mix time (8 seconds and 12
seconds in the example).
I need only a pause time,
no mix
Set mix time at zero. Set pause time at
the desired value.
Mix light is off.
Pause light is on.
The two displays show pause time.
Maintenance
6. Maintenance
6.1. Maintenance allowed to the user
6.1.1. Every week
•
Clean machine body with a soft non abrasive cloth.
WARNING: Do not use aggressive detergents or sol-
vents that may ruin machine parts
•
Verify visually that steam, condensate and compressed air
connections do not leak
• Verify that visible electrical cabling and air and steam
connection tubing are in perfect working order
•
Verify that pads and covers are in good condition. If they show
any sign of deterioration replace them immediately. Pressing
quality may decrease dramatically if pads and covers are dirty
or damaged.
•
Clean the filter (only types with boiler)
Refer to Figure 6.1
•
Close the connections to the water source.
•
Remove the elbow fitting (R).
•
Clean the fitting.
•
Remove the filter (S).
•
Carefully clean the filter.
•
For types with boiler: once a week, after finishing ironing, dis-
charge the boiler following the instructions at the following
paragraph.
WARNING: Do not run a machine that does not look in
proper order
INDICATION: always ask for original spare parts. Non
original parts may damage to the machine or decrease
its safety
6.1.2. Boiler discharge procedure
The boiler discharge is a delicate procedure, that may be dangerous
if carried out in improper way.
Figure 6.1 - Water filter cleaning (only machine with built-in boiler)
Table 5.2 - Advanced programming parameters
Parameter
number
Parameter description
Meaning of the number in the display AIR
(press + or - to change the value)
01
Manual steam time. Duration of steam output when pressing the
steam button in the manual controls section. The factory pre-set time
is 0 seconds.
Time of manual steam in seconds
Summary of Contents for 5040 EASYFORM
Page 2: ...50xx Easyform ed0811 ...
Page 4: ...50xx Easyform ed0811 ...
Page 18: ...50xx Easyform ed0811 50xx EASYFORM 18 ...
Page 22: ...50xx Easyform ed0811 50xx EASYFORM 22 Diagrams ...
Page 24: ...50xx Easyform ed0811 50xx EASYFORM 24 Diagrams ...
Page 26: ...50xx Easyform ed0811 50xx EASYFORM 26 Diagrams ...
Page 28: ...50xx Easyform ed0811 50xx EASYFORM 28 Diagrams ...