background image

 

12 

-

 

During  operation,  the  product  will  automatically  switch  on  and  off  periodically  to  maintain  a  constant 
level of humidity in the environment. 

-

 

After  use  press  the  POWER  button,  then  unplug  the  unit  from  the  power  outlet.  Do  not  leave  the  plug 
inserted unnecessarily. 

-

 

If  you  turn  off  the  appliance,  wait  at  least  3  minutes  before  switching  on  again,  in  order  to  protect  the 
compressor from damage. 

HUMIDITY REGULATION 

Humidity can be set between 40% and 80%. 
-

 

Press SETTING button on panel (2). On display a number flashes; it indicates humidity currently set.  

-

 

To change setting press SETTING button until reaching the desired value.  

-

 

Wait 5 seconds without pressing any key. 

-

 

During operation, the product will automatically switch on and off periodically to maintain a constant level 
of humidity in the environment. 

TIMER 

Product has a 24 hours timer 
-

 

Press TIMER button on panel (2). On display appears “00”.  

-

 

To set timer, press TIMER button until reaching the desired time.  

-

 

Wait 5 seconds without pressing any key. Appliance will automatically switch off after the hours set. 

 

DEFROST 

When  the  dehumidifier  works  for  too  long  or  it  is  used  in  environments  with  low  room  temperatures,  the 
antifreeze function (Defrost) it may work. This function prevents freezing of the evaporator located inside the 
product, when it tends to freeze, defrost function turns off the device periodically detaining dehumidification. 
 

WATER DRAINAGE 

When the unit  collects moisture from the environment, the water can be discharged in the water tank (5), if 
the container is correctly mounted in its housing, or it can be drained continuously. 

Continuous drain

 

If you want to operate the dehumidifier for a long time in the same environment, often 
without having to empty the container, you can drain the water continuously through a 
plastic tube with an inner diameter of 10mm (not included). 
Follow the steps below:  
-

 

Remove water tank (5) and insert the plastic tube on the water outlet located up-left 
in the water tank space; then install the water tank (5) again.  

-

 

Bring the plastic tube into a drainage container, taking care to keep the pipe always 
facing down. 

CAUTION

: whether you operate the unit in continuous drain mode or not, always place 

the water tank (5) in its housing, otherwise the product will not work. 
 

EMPTY THE WATER TANK 

The red light " FULL" on the control panel  (2) indicates that water container is full or not 
installed correctly. In this case, remove water tank (5), remove the water and reassemble it 
correctly in place. 

CAUTION: the water collected in the  tank can be used as distilled water for ironing. 
Do not drink the exhausted water for any reason, and/or use it for another purpose. 
 

AIR FILTER 

Unplug unit from the electrical outlet before pulling out the filter.  

Mounted to the air inlet grill (4) is located a filter that purifies the air coming out. If you use the product on a 
regular basis  clean  the  filter  every  2  weeks.  To do  so,  remove  the  grill  by pulling  it up.  Wipe  with  a  damp 
cloth or wash with warm water. In any case, let it dry completely before installing it back. 

Summary of Contents for G3 FERRARI SPUGNA 20

Page 1: ...Deumidificatore Dehumidifier SPUGNA 20 MANUALE D USO MOD G90072 Technical model D018R2C 20L www g3ferrari it IT EN PT DE USER MANUAL...

Page 2: ...stiche tecniche p 8 Informazioni sul gas p 8 Trattamento dei rifiuti delle apparecchiature elettriche ed elettroniche p 26 ENG INDEX Symbols p 2 Safety instructions p 8 General information p 10 G90072...

Page 3: ...anti ad alta tensione non apritelo in nessun caso This symbol warns the user that un insulated dangerous voltage inside the system may cause an electrical shock Do not open the case Questo simbolo ind...

Page 4: ...ricordiamo che questi devono essere oggetto di raccolta differenziata Accertarsi che i dati di targa siano compatibili con quelli della rete elettrica l installazione deve essere effettuata in base al...

Page 5: ...con ridotte capacit fisiche sensoriali o mentali o con mancanza di esperienza o conoscenza se a loro stata assicurata un adeguata sorveglianza oppure se hanno ricevuto istruzioni circa l uso in sicure...

Page 6: ...Vuotare il contenitore prima di spostare il prodotto per spostarlo utilizzare le ruote e l apposita maniglia Prima di utilizzare il prodotto asciugarlo e controllare che non vi siano tracce di bagnat...

Page 7: ...apparecchio tenere il prodotto spento in posizione verticale per circa 24 ore in modo da lasciar depositare oli e gas Durante il funzionamento il compressore produce calore Ci pu risultare in un liev...

Page 8: ...e il tubo di drenaggio nel foro di scarico 8 posto in alto a sinistra nel vano del serbatoio reinserire la vaschetta 5 nel suo alloggio Portare quindi il tubo in plastica in un contenitore di drenaggi...

Page 9: ...one antigelo e rilevamento serbatoio pieno Controllo elettronico con timer e regolazione umidit Temperatura d uso 5o C 35o C INFORMAZIONI SUL GAS Il gas utilizzato per il funzionamento del deumidifica...

Page 10: ...mains when the device is not in use Always disconnect from power supply if you leave it unattended Cleaning operations should be carried out after unplugging the unit If the unit is out of order and...

Page 11: ...ended to be operated by means of an external timer or separate remote control system Before every use unroll the power cord Use original spare parts and accessories only Do not subject the product to...

Page 12: ...ainer 6 Air inlet grill 7 Wheels 8 Continuous water out spout 9 Power cable CONTROL PANEL POWER to switch on and off appliance SWING to activate the air outlet deflector SETTING to set humidity desire...

Page 13: ...collects moisture from the environment the water can be discharged in the water tank 5 if the container is correctly mounted in its housing or it can be drained continuously Continuous drain If you w...

Page 14: ...dehumidifier is located on a stable surface The filter is dirty The unit turns off during operation Room is too hot or too cold TECHNICAL FEATURES Power supply AC 230V 50Hz Power 310W Water tank capac...

Page 15: ...rem conformes s normas de seguran a em vigor em qualquer caso nunca ultrapassar os limites de absor o indicados no adaptador e ou nas extens es nem os de m xima pot ncia indicados nos adaptadores m lt...

Page 16: ...crian as n o devem brincar com o aparelho Mantenha o aparelho e o cabo de alimenta o fora do alcance de crian as com menos de 8 anos de idade Se o cabo de alimenta o estiver danificado ou em caso de f...

Page 17: ...o aparelho deixar de funcionar ou os filtros estragarem entrar em contacto com o centro de assist ncia autorizado Utilizar somente pe as e acess rios originais N o utilizar em caso de perda de leo ou...

Page 18: ...unidade ligada Ele tamb m acende se um dos espi es HI o LOW dependendo da velocidade do ventilador ajustada anteriormente Para mudar a velocidade pressione a tecla SPEED Durante o funcionamento o apar...

Page 19: ...a gua e montar corretamente no seu lugar ATEN O A gua recolhida no reservat rio pode ser utilizada como agua destilada para ferros de passar Esta a sua nica utiliza o poss vel n o ingerir em caso algu...

Page 20: ...Hersteller kann f r Sch den haftbar gemacht werden die durch eine unsachgem e falsche oder unvern nftige Verwendung verursacht werden Stellen Sie vor der Verwendung sicher dass das Ger t unversehrt i...

Page 21: ...Falle von Kurzschl ssen nicht und lassen Sie es in einer Vertragswerkstatt reparieren Setzen Sie das Ger t keinen ung nstigen Wetterbedingungen wie z B Regen Feuchtigkeit Frost aus und bewahren Sie es...

Page 22: ...lich auf Grifffl chen die abhalten und verwenden Sie solche Hitzeschutzma en Dieses Ger t ist nur f r den Hausgebrauch oder gleichwertiges bestimmt in Situationen wie bspw Kantinen in kleinen Firmen...

Page 23: ...Gehen Sie bei der Installation wie folgt vor Halten Sie den Entfeuchter immer in einer aufrechten Position und legen Sie ihn auf eine stabile und ebene Oberfl che Achten Sie immer auf eine gute Bel ft...

Page 24: ...Sie dann den Netzstecker heraus Lassen Sie den Stecker nicht unn tig stecken Wenn Sie das Ger t ausschalten warten Sie mindestens 3 Minuten bevor Sie es wieder einschalten um den Kompressor vor Besch...

Page 25: ...rwenden Sie es f r einen anderen Zweck LUFTFILTER Ziehen Sie den Netzstecker aus der Steckdose bevor Sie den Filter herausziehen Am Lufteinlassgitter 4 befindet sich ein Filter der die Luft ausgibt We...

Page 26: ...zt Das Ger t schaltet sich w hrend des Betriebs aus Das Zimmer ist zu hei oder zu kalt TECHNISCHE MERKMALE Stromversorgung AC 230V 50Hz Strom 310W Wassertankkapazit t 3 Lt Feuchtigkeitsentfernung 30o...

Page 27: ...cedures for disposal The crossed out wheelie bin symbol indicates the product complies with the requirements of the new directives introduced to protect the environment 2002 96 EC 2003 108 EC 2002 95...

Page 28: ...l si riserva il diritto di apportare a questi apparecchi modifiche ELETTRICHE TECNICHE ESTETICHE e o sostituire parti senza alcun preavviso ove lo ritenesse pi opportuno per offrire un prodotto sempr...

Reviews: