background image

 

11 

-

 

Before you pull the plug off, turn the unit off by using the proper control knob. 

-

 

Cleaning operations should only be performed before having unplugged the unit and always following the 
specific instructions. 

-

 

Do not pull the power cord to disconnect the plug. 

-

 

If  the  product  stops  operating  or  filters  have  been  exhausted,  contact  a  service  center.  Using  original 
accessories is recommended. 

-

 

Do not use in case of leakage of oil or gas, do not remove the float in the water container. 

-

 

Periodically remove the water collected in the container. Do not drink it for any reason, but use it as 
distilled water for irons. 

During installation, follow the steps below: 
-

 

Always keep the dehumidifier in an upright position and place it on a stable and level surface. 

-

 

Always ensure a good ventilation: do not obstruct the air grids, leave enough space at both sides of the unit 
and clean the filters regularly. 

-

 

Do not place in closets or too small rooms. 

-

 

Use in environments with room temperatures between 5 ° C and 35 ° C. 

-

 

Do  not  place  the  product  near  heaters  or  heat  or  exposing  it  to  direct  sunlight.  Do  not  use  at  too  low 
temperatures to prevent freezing of internal parts. 

-

 

Do not use as a storage shelf for objects. 

-

 

The  appliance  should  not  be  exposed  to  adverse  weather  conditions  (such  as  rain,  wind,  humidity,  frost, 
etc...); do not place it on or near open windows. 

 

DESCRIPTION G90072 

1. Handle  

 

2. Control panel 

 

 

3. Filter   

4. Air outlet 

 

5. Water container   

 

6. Air inlet grill 

 

7. Wheels 

 

8. Continuous water out spout 

9. Power cable 

 

CONTROL PANEL 

POWER

: to switch on and off appliance 

SWING

: to activate the air outlet deflector 

SETTING 

: to set humidity desired in the room 

TIMER 

: to set the 24 hours timer. 

SPEED

: to select fan speed 

Light “

power

”: Color green, it switches on when product is linked to power supply. 

Light “

full

”: Color red, it switches on if the water tank is full or not properly inserted. 

Light “

Swing

”: Color green, it switches on if the deflector is moving. 

Light “

timer

”: Color green, it switches on when timer is set. 

Light “

HI

”: Color green, it indicates that the fan is running at high speed. 

Light “

LOW

”: Color green, it indicates that the fan is running at low speed. 

DISPLAY

: the 2 numbers display can indicate: 

-

 

Humidity sensed in the room during use 

-

 

Humidity set with button “SETTING” 

-

 

The hours set with TIMER 

 

OPERATING

 

Before operating the unit, follow installation instructions found on page 11 of this user manual. On first use, 
and after having moved the unit, keep off dehumidifier in a vertical position for about 24 hours, so as to settle 
oil and gas. During operation, compressor make heat. This can result in a slight increase in room temperature. 
-

 

Make sure that the  water tank (5) is empty. Connect the unit to the power outlet. The lamp "Power" on 
panel (2) lights on and the display indicates the humidity of the room. 

-

 

Press the button POWER on the panel (2). If the humidity in the room is more than the humidity set, the 
appliance  switches  on.  Also  the one  of  the  lights  “HI”  or  “LOW”  light  up,  depending  on  the  fan speed 
previously set. To change the speed of fan, press the button SPEED. 

Summary of Contents for G3 FERRARI SPUGNA 20

Page 1: ...Deumidificatore Dehumidifier SPUGNA 20 MANUALE D USO MOD G90072 Technical model D018R2C 20L www g3ferrari it IT EN PT DE USER MANUAL...

Page 2: ...stiche tecniche p 8 Informazioni sul gas p 8 Trattamento dei rifiuti delle apparecchiature elettriche ed elettroniche p 26 ENG INDEX Symbols p 2 Safety instructions p 8 General information p 10 G90072...

Page 3: ...anti ad alta tensione non apritelo in nessun caso This symbol warns the user that un insulated dangerous voltage inside the system may cause an electrical shock Do not open the case Questo simbolo ind...

Page 4: ...ricordiamo che questi devono essere oggetto di raccolta differenziata Accertarsi che i dati di targa siano compatibili con quelli della rete elettrica l installazione deve essere effettuata in base al...

Page 5: ...con ridotte capacit fisiche sensoriali o mentali o con mancanza di esperienza o conoscenza se a loro stata assicurata un adeguata sorveglianza oppure se hanno ricevuto istruzioni circa l uso in sicure...

Page 6: ...Vuotare il contenitore prima di spostare il prodotto per spostarlo utilizzare le ruote e l apposita maniglia Prima di utilizzare il prodotto asciugarlo e controllare che non vi siano tracce di bagnat...

Page 7: ...apparecchio tenere il prodotto spento in posizione verticale per circa 24 ore in modo da lasciar depositare oli e gas Durante il funzionamento il compressore produce calore Ci pu risultare in un liev...

Page 8: ...e il tubo di drenaggio nel foro di scarico 8 posto in alto a sinistra nel vano del serbatoio reinserire la vaschetta 5 nel suo alloggio Portare quindi il tubo in plastica in un contenitore di drenaggi...

Page 9: ...one antigelo e rilevamento serbatoio pieno Controllo elettronico con timer e regolazione umidit Temperatura d uso 5o C 35o C INFORMAZIONI SUL GAS Il gas utilizzato per il funzionamento del deumidifica...

Page 10: ...mains when the device is not in use Always disconnect from power supply if you leave it unattended Cleaning operations should be carried out after unplugging the unit If the unit is out of order and...

Page 11: ...ended to be operated by means of an external timer or separate remote control system Before every use unroll the power cord Use original spare parts and accessories only Do not subject the product to...

Page 12: ...ainer 6 Air inlet grill 7 Wheels 8 Continuous water out spout 9 Power cable CONTROL PANEL POWER to switch on and off appliance SWING to activate the air outlet deflector SETTING to set humidity desire...

Page 13: ...collects moisture from the environment the water can be discharged in the water tank 5 if the container is correctly mounted in its housing or it can be drained continuously Continuous drain If you w...

Page 14: ...dehumidifier is located on a stable surface The filter is dirty The unit turns off during operation Room is too hot or too cold TECHNICAL FEATURES Power supply AC 230V 50Hz Power 310W Water tank capac...

Page 15: ...rem conformes s normas de seguran a em vigor em qualquer caso nunca ultrapassar os limites de absor o indicados no adaptador e ou nas extens es nem os de m xima pot ncia indicados nos adaptadores m lt...

Page 16: ...crian as n o devem brincar com o aparelho Mantenha o aparelho e o cabo de alimenta o fora do alcance de crian as com menos de 8 anos de idade Se o cabo de alimenta o estiver danificado ou em caso de f...

Page 17: ...o aparelho deixar de funcionar ou os filtros estragarem entrar em contacto com o centro de assist ncia autorizado Utilizar somente pe as e acess rios originais N o utilizar em caso de perda de leo ou...

Page 18: ...unidade ligada Ele tamb m acende se um dos espi es HI o LOW dependendo da velocidade do ventilador ajustada anteriormente Para mudar a velocidade pressione a tecla SPEED Durante o funcionamento o apar...

Page 19: ...a gua e montar corretamente no seu lugar ATEN O A gua recolhida no reservat rio pode ser utilizada como agua destilada para ferros de passar Esta a sua nica utiliza o poss vel n o ingerir em caso algu...

Page 20: ...Hersteller kann f r Sch den haftbar gemacht werden die durch eine unsachgem e falsche oder unvern nftige Verwendung verursacht werden Stellen Sie vor der Verwendung sicher dass das Ger t unversehrt i...

Page 21: ...Falle von Kurzschl ssen nicht und lassen Sie es in einer Vertragswerkstatt reparieren Setzen Sie das Ger t keinen ung nstigen Wetterbedingungen wie z B Regen Feuchtigkeit Frost aus und bewahren Sie es...

Page 22: ...lich auf Grifffl chen die abhalten und verwenden Sie solche Hitzeschutzma en Dieses Ger t ist nur f r den Hausgebrauch oder gleichwertiges bestimmt in Situationen wie bspw Kantinen in kleinen Firmen...

Page 23: ...Gehen Sie bei der Installation wie folgt vor Halten Sie den Entfeuchter immer in einer aufrechten Position und legen Sie ihn auf eine stabile und ebene Oberfl che Achten Sie immer auf eine gute Bel ft...

Page 24: ...Sie dann den Netzstecker heraus Lassen Sie den Stecker nicht unn tig stecken Wenn Sie das Ger t ausschalten warten Sie mindestens 3 Minuten bevor Sie es wieder einschalten um den Kompressor vor Besch...

Page 25: ...rwenden Sie es f r einen anderen Zweck LUFTFILTER Ziehen Sie den Netzstecker aus der Steckdose bevor Sie den Filter herausziehen Am Lufteinlassgitter 4 befindet sich ein Filter der die Luft ausgibt We...

Page 26: ...zt Das Ger t schaltet sich w hrend des Betriebs aus Das Zimmer ist zu hei oder zu kalt TECHNISCHE MERKMALE Stromversorgung AC 230V 50Hz Strom 310W Wassertankkapazit t 3 Lt Feuchtigkeitsentfernung 30o...

Page 27: ...cedures for disposal The crossed out wheelie bin symbol indicates the product complies with the requirements of the new directives introduced to protect the environment 2002 96 EC 2003 108 EC 2002 95...

Page 28: ...l si riserva il diritto di apportare a questi apparecchi modifiche ELETTRICHE TECNICHE ESTETICHE e o sostituire parti senza alcun preavviso ove lo ritenesse pi opportuno per offrire un prodotto sempr...

Reviews: