1. Turn OFF the power at the
circuit breaker and confirm
with the voltage tester at the
switch before proceeding.
Place voltage tester against
the existing switch checking
the wall plate, screws and
switch at various points to
determine that there is no
power present.
2. Remove the wall plate and
pull out the existing light
switch so that all wires
are exposed outside of the
gang box (do not disconnect
wires).
3. Label the live wire with a
piece of electrical tape.
Installation
Piece of
electrical tape
Different color screw
(Black or Copper)
Single Pole
3-Way
OFF
ON
OFF
ON
OF
F
ON
OF
F
ON
Summary of Contents for TLWZ-SNC-01