background image

10 

IQ41x Installation Instructions - Confi guring TG201251 Issue 5, 22-Aug-2014

IQ41x

InstallationInstructions-Configuring

 3

Make Connection

 1

Switch off

2

openRotatingCovers

 3 

CoNNECt to IQ4

O

I

PC via Local Engineering Port (USB)

USB cable

Micro B USB connector

Connect Directly to Controller

PC via Ethernet Port

Connection use

Notes

IPTool

ü

SET

ü

Requires vCNC

Web Browser

ü

Supervisor

ü

Requires vCNC

PC via Local Supervisor Port (RS232)

Connection to IQ4 can be made directly via the RS232 Local Supervisor Port, USB Local Engineering Port, or Ethernet Port. 

Connection can also be made over a network (Ethernet).

Connection use

Notes

IPTool

SET

ü

Web Browser

Supervisor

Connection use

Notes

IPTool

SET

ü

Web Browser

Supervisor

ü

IQView8 via Local Supervisor Port (RS232)

IQView8 requires its own power supply.

Note: If local supervisor port address is ‘0’ (default) 

communication is limited to the IQ4. If non-zero, communication 

is possible over the entire network. 

RJ45

Standard Ethernet cable 

(Cat 5e twisted pair)

max 100 m (109 yds) 

RJ45

Cable/EJ101442

9 way female 

D type

RJ11

PC 

IQView8

RJ11

RJ11

CABLE/EJ105650

Draft

Summary of Contents for IQ41 Series

Page 1: ...Applet Manual TE201298 IQTool Addresser Applet Manual TE201299 IQ4 Configuration Manual TE201263 Note PDF copies are included with SET installation in the following folder C Trend Control Systems Docu...

Page 2: ...Re continued Serial Number n q 4 e y e c p 4 1 2 3 4 5 Q411B_V53440388 O S Q411B_V53440388 n q 4 e y e c p 4 1 2 3 4 5 00 10 70 0D 1E 92 MAC Addr IQ411 1010U5000 Part No LAN 4 MAC Addr IP Addr LAN Loc...

Page 3: ...d 22 23 24 25 RX 28 29 WMB RX TX TX RX OK 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 230V 19 4 5 10 24V 0V 0V 0V 0V 0V 0V 9 8 6 7 1 2 3 Watchdog red Power green 11 Check ethernet LeDs if Ethernet is...

Page 4: ...addressing the unit automatical obtains its IP addressing details IP address subnet mask default router WINS server and DNS server from the network s DHCP Dynamic Host Configuration Protocol server I...

Page 5: ...run the IQTool Addresser Applet and click to run the Discovery Wizard Select either Automatic Discovery recommended or Manual Discovery If Automatic Discovery was selected you should also select Dupl...

Page 6: ...IQTool Monitor Applet Manual TE201298 20 Set up Additional Trend Addressing if required IQTool Monitor Applet Manual TE201298 If the IQ41x is to provide a network connection for supervisors and tools...

Page 7: ...nd switch off all other devices on the network If still OFF check network cabling for short circuits with a multimeter NOT Megger If ON switch on other devices until faulty device found i e OK LED goe...

Page 8: ...9k6 Note SET will set up the controller s date and time to that of the PC during download However they may be set up from a controller configured as timemaster Configure the strategy using SET and te...

Page 9: ...supervisors tools and displays as described in Connect to IQ4 on page 10 Connection of PCs displays etc can be made directly to controller via the RS232 Local supervisor Port USB Local Engineering Por...

Page 10: ...o IQ4 can be made directly via the RS232 Local Supervisor Port USB Local Engineering Port or Ethernet Port Connection can also be made over a network Ethernet Connection use Notes IPTool SET Web Brows...

Page 11: ...vice on the same Ethernet Trend network Note If connecting with IP Tool the PC should be on the same Ethernet segment as the IQ4 Note To make a connection with a web browser use IQ4 s IP address or ho...

Page 12: ...r steps 1 to 5 of the Installation Configuring section 5 DISPoSAL WEEE Directive At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre Do not d...

Reviews: