12
IQ41x Installation Instructions - Confi guring TG201251 Issue 5, 22-Aug-2014
IQ41x
InstallationInstructions-Configuring
Please send any comments about this or any other Trend technical publication to [email protected]
©
2014 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls
Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation
to notify any person of such revisions or changes.
trendControlSystemsLimited
Albery House, Springfi eld Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com
trendControlSystemsuSA
6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel:(425) 869-3900 Fax:(425) 869-8445 www.trend-americas.com
3
Reset Controller
4
Re-configureController
2
CloseRotatingCovers
1
open Panel
4
ReSettoDeFAuLtS
Switch Off, Isolate I/O, Open Panel, Open Rotating Covers,
and Disconnect I/O as per steps (1) to (5) of the ‘Installation
- Confi guring’ section.
5
DISPoSAL
WEEE Directive:
At the end of their useful life the packaging and
product should be disposed of by a suitable
recycling centre.
Do not dispose of with normal household waste.
Do not burn.
Re-confi gure controller as described in these instructions.
Press and hold down the service button,
the service button
LED will fl ash
.
While continuing to hold down the button,
switch on the controller. Ensure the button remains pressed
for 2 to 5 s after power is switched on. Do not switch off the
controller for at least 1 minute.
O
I
2 to 5 s
22
23
24
25
RX+
28
29
WMB
RX- TX+ TX-
RX
OK
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
230V
19
4
5
10
24V
0V
0V
0V
0V
0V
0V
9
8
6
7
1
2
3
Press
22
23
24
25
RX+
28
29
WMB
RX- TX+ TX-
RX
OK
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
230V
19
4
5
10
24V
0V
0V
0V
0V
0V
0V
9
8
6
7
1
2
3
Release
WARNING FoR /230 versions:
Hazardous
voltages exist in this area when the unit is
powered. This operation should only be performed
after taking suitable precautions
The strategy, user modules (passwords, PINs etc), alarm logs,
and plots are cleared down and the following parameters set
to defaults:
Lan number,
outstation address
IP addressing mode
IP address,
subnet mask
UDP port
identifi er
Router 1
remote Trend devices,
Virtual vCNC).
Backdrop fi les are unchanged and time and date left at their
current settings.
Draft