ZPHA Installation Guide 

1

Prepare the site

Before installing the ZPHA device, refer to all the site safety and compliance requirements in the 

TippingPoint Hardware Safety and Compliance Guide

, in addition to the requirements that follow.

“Ventilation and location” on page 1

“Power requirements” on page 1

“System grounding requirements” on page 1

“Cabling requirements” on page 2

“Unpack the ZPHA device” on page 2

Ventilation and location

Ventilation and proper location are essential to the proper operation of the product. Follow these 
guidelines to ensure that the product receives adequate ventilation.

The ZPHA device should be located near the IPS or TPS device in the rack. The ZPHA device 
connects to the IPS/TPS device through the following:

Nonstandard USB cable for power

Network cables to receive and transmit network traffic

Do not connect a single ZPHA device to more than one IPS or TPS device with the nonstandard 
USB power cable. The ZPHA device requires only one USB connection for power.

Power requirements 

The TippingPoint ZPHA device receives power through a nonstandard USB cable connected to the 
IPS or TPS device. The ZPHA device comes with this nonstandard USB cable. 

Depending on the model, the USB ports are located on the front or the back of the device. The 
ZPHA device does not require any other type of power connection to function.

System grounding requirements

Damage from Electromagnetic Static Discharge (ESD) can occur when electronic components are 
improperly handled. This could result in complete or intermittent system failures. Therefore, proper 
ESD protection is required whenever you handle IPS or TPS devices and equipment. It is not 
necessary to open the ZPHA device chassis to add or remove any components.

NOTE: 

When you install the ZPHA device, you do not need to modify or open the IPS or TPS 

chassis. You will only need to connect cables during installation procedures.

The following general grounding guidelines apply in the event that a power supply module or high 
availability module must be replaced.

Always use an ESD wrist strap when adding or removing components from the chassis.

Avoid touching the circuit boards or connectors on all cards and modules.

Avoid contact between the printed circuit boards and clothing. The wrist strap only protects 
components from ESD voltages on the body. ESD voltages on clothing can still cause damage.

Place a removed component board-side-up on an antistatic surface or in a static-shielding 
container that is also grounded to the same point as the IPS or TPS device. If you plan to return 
the component to the factory, immediately place it in a static-shielding container.

Summary of Contents for TippingPoint ZPHA

Page 1: ...Part Number APEM07687 170111 TippingPoint Zero Power High Availability Installation Guide Modular and Non modular...

Page 2: ...m collects and provides detailed instructions on how to disable the specific features that feedback the information Legal Notice Copyright 2018 Trend Micro Incorporated All rights reserved Trend Micro...

Page 3: ...e located on the front or the back of the device The ZPHA device does not require any other type of power connection to function System grounding requirements Damage from Electromagnetic Static Discha...

Page 4: ...PHA system complete the following steps 1 Inspect the packing container If you see any damage or other signs of mishandling inform both the local freight provider and TippingPoint before unpacking You...

Page 5: ...ot inspected or blocked This section includes the following topics ZPHA device hardware overview on page 3 ZPHA device installation on page 7 Crossover cable installation on page 13 ZPHA device hardwa...

Page 6: ...A device includes one type A and one type B USB port while the non modular ZPHA device includes two type B USB ports You can connect the IPS or TPS device to the ZPHA device through the A or B USB typ...

Page 7: ...n take longer to establish the link As a best practice record the required link times of the network equipment connected to the ZPHA device Use this data to tune your network switching configurations...

Page 8: ...ows the fiber segment modules Figure 2 5 Fiber segment modules 1 Zero Power HA Fiber Segment Module 2 Zero Power HA v2 Fiber Segment Module The following image shows the copper segment module Figure 2...

Page 9: ...the ZPHA device continues to route network traffic to the device and the IPS TPS device blocks the traffic until the reboot sequence completes After the reboot sequence completes reconnect the nonstan...

Page 10: ...The vertical hole spacing on the rack rails must meet standard EIA 310 C requirements which call for one inch 2 54 cm spacing 2 After installing the system case place a segment module into a segment...

Page 11: ...e network traffic through the ZPHA device to the IPS TPS device Connect a cable from port A of the IPS TPS device to port A of the ZPHA device segment Connect a cable from port B of the IPS TPS device...

Page 12: ...e and that traffic is passing through the ZPHA device If traffic is not passing you might need to use a crossover cable instead of a straight cable for one of the network connections See Crossover cab...

Page 13: ...rd 19 or 23 inch rack The vertical hole spacing on the rack rails must meet standard EIA 310 C requirements which call for a one inch 2 54 cm spacing 2 Connect the RJ 45 copper cables to route network...

Page 14: ...in configuration Use a daisy chain configuration to connect multiple ZPHA devices to a single IPS or TPS device A daisy chain setup might be necessary if you need ZPHA device protection for more than...

Page 15: ...k devices connected to the ZPHA device are not auto MDIX enabled you might still need to use a crossover cable in your configuration The following figures display different installations of the ZPHA d...

Page 16: ...k configuration For example if the network devices connected to the ZPHA device are both DTE devices or both DCE devices use a crossover cable to connect one of the network devices to the ZPHA device...

Reviews: