Receiver Card for the Hunter
ICC
Installation Instructions:
Step 1:
Remove power from controller first!
Step 2: Open the front panel door of the controller and clean the
bottom inner portion of the door.
Step 3: Remove the backing paper from the double-sided tape on
the back of the Receiver Card and firmly place the Card
onto the spot you have just cleaned. (BNC antenna mount
lines up toward the left as illustrated in
fig.1
below).
Step 4: Connect the 3 wires to the terminals in the upper left module
on the back panel of the controller as follows: (See
fig.2
).
Blue: to the REM terminal (sometimes labeled simply “R”)
White: to the upper AC terminal
Red: to the lower AC terminal
Step 5: Connect the antenna to the BNC fitting on the Receiver
Card (Make sure the antenna points upward as illustrated in
fig. 1
below). For additional range, install the top mount
antenna w/coaxial cable into the top of the controller (see
antenna mounting instructions in the top-mount antenna kit).
Step 6: Mount the adhesive “wire tie-down” to the right side of the
inner door panel (see
fig.1
) and route the wires and cable
through it, leaving slack so that NO strain is placed on wires
when door is being opened.
Step 7: Re-apply power and check the remote for operation.
antenna
antenna mount
tie-down
blue wire
white wire
red wire
Fig 2
Fig. 1
18
800-275-8558 www.remotecontroltech.com
Receiver Number
The TRC Commander Transmitter can operate as many as 199
Permanent Receivers on each group code. To designate
Receiver press a desired Receiver number and "Rec #" key.
Setting to Receiver number 3:
To turn Master Valve off:
To turn Master Valve on:
9
9
VALVE
OFF
VALVE
ON
9
9
REC
#
3
Operating the Pump Start/Master Valve
When in the automatic mode, the Pump Start/Master Valve is auto-
matically activated when a valve station is turned on. You can manu-
ally turn on the Pump Start/Master Valve by pressing "99" "Valve
On". IF YOU MANUALLY TURN ON THE PUMP START/MASTER
VALVE STATION, YOU MUST MANUALLY TURN IT OFF AGAIN.
There is no default time with this function. The Pump Start/MV will
stay on until "0" "Valve Off" or "99" "Valve Off" command is received.
Press the two digits "99" "Valve On" to select only the Pump Start/
Master Valve station. To turn off the pump start/master valve station
press the two digit "99" "Valve Off" key to deactivate.
11