For 2 minutes:
For 20 minutes:
For 2 Hours:
Master Valve Off
When a valve station is activated the Pump Start/Master Valve is
automatically enabled by the Receiver. To disable the Master Valve
press the "MV Off" key. Pressing the "MV Off" key again prior to
turning on any stations at a Receiver will turn the Master Valve back
on.
Note: Using "99" "Valve On" to manually operate the Pump Start/
Master Valve will override the "MV Off" function. It will also run the
Master Valve/Pump Start continuously.
To disable the Master Valve:
0
0
TIME
TIME
2
0
0
0
2
TIME
2
MV
OFF
0
Time Duration
You can set a time duration anywhere from two minutes to two hours.
Press three digits of time in the following format:
Hour, Tens Minutes, Minutes. The range of allowed entries for time
duration is from two minutes "002" to two hours "200". Then press
the "Time" key, followed by the desired zone # and then "Valve On."
Hour Tens Minutes
10
800-275-8558 www.remotecontroltech.com
Receiver Cards for the
Superior Sterling
Installation Instructions:
Step 1:
Remove power from controller first!
Step 2: Remove the controller faceplate by unscrewing the
cross-recessed screws on each side.
Step 3: Clean upper left, inner side panel (inside controller, behind
front panel). Remove the backing from the tape on the back
of the Receiver Card and firmly press the Card onto
the spot you just cleaned. (Not illustrated here).
Step 4: Connect the interface cable (with white connector) from the
Card into the six pin molex connector on the back right-hand
side of controller face (not illustrated here).
Step 5: Connect the antenna to the BNC fitting on the Receiver
Card or connect the external mount antenna with coax cable
for max. range.
Step 6: Connect all of your field common wires to the silver screw
terminal on the card, then connect the black wire on on the
Card to a "valve common" terminal on the controller.
Step 7: Re-install the controller face plate.
Step 8: Re-apply power and check the remote for operation.
antenna
interface cable
field common wires go here
black wire
connects to
valve com-
mon here
800-275-8558 www.remotecontroltech.com
19