CoolMod Operation
There are four types of modules (standard, bulk, dual, and wide-trim) that can be
used with either CoolPac option. These modules provide discrete isolated DC outputs
that can be individually controlled. For module output specifications, refer to
“Electrical Specifications”
on page 3
‑
2.
C
CO
OO
OLLM
MO
OD
D SSTTAAR
RTTU
UPP AAN
ND
D SSH
HU
UTTD
DO
OW
WN
N
When input power is applied, standard CoolMod outputs rise to their setpoint voltage
simultaneously. When input power is removed, standard CoolMod outputs begin
turning off simultaneously. Outputs can be sequenced using the enable function in
order to allow controlled start up if required. The following table contains the
maximum startup delays for all modules.
TTaabbllee 66‑‑88.. Startup delays for modules
SSttaarrttuupp C
Coonnddiittiioonn
M
Maaxxiim
muum
m SSttaarrttuupp D
Deellaayy ((m
mss))
From AC
1000
From global
ENABLE
(control)
20
From module
ENABLE
20
PPO
OW
WEER
R R
RAATTIIN
NG
GSS
When selecting a power supply for an application, it is necessary to ensure that the
supply operates within its power capabilities. You must consider both temperature
derating and input voltage derating. The CoolX unit will deliver 100% rated power
from −20°C to 40°C (−4°F to 104°F) in free air (natural convection cooling) with no
external fans, and will deliver 25% output power up to 85°C (185°F). Input voltage
derating and temperature derating curves follow.
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Installation, Setup, and Operation
6‑14