   Designers Manual                        

 

 

                                                       Advanced Energy CoolX600 Series

EEM

MC

C  C

CR

RIITTEER

RIIAA

There are four criteria levels, each referring to a specific performance level of the 

product during and after the EMC phenomenon is applied. These are specifically 

observed during immunity testing and are described in the following table:

TTaabbllee  11‑‑44..  EMC criteria

C

Crriitteerriiaa  LLeevveell

D

Deessccrriippttiioonn

A

The apparatus shall continue to operate as intended. 

No degradation of performance or loss of function is 

observed during or after the test.

B

The apparatus shall continue to operate as intended 

after the test. No degradation of performance or loss 

of function is allowed below a performance level 

specified by the manufacturer when the apparatus is 

used as intended. During the test, temporary 

degradation of performance is allowed if it is self 

recoverable.

C

Temporary loss of function is allowed during and after 

the test that requires operator intervention to restore 

the product/apparatus to normal operation.

D

During the test, loss of function that is not recoverable 

occurs.

AAD

DD

DIITTIIO

ON

NAALL  EEM

MII  C

CH

HAAR

RAAC

CTTEER

RIIZZAATTIIO

ON

N

CoolX units are compliant with SEMI F47 for voltage dips and interruptions. Input 

voltage must be > 180 VAC.
Contact Advanced Energy Global Services for additional details.

G

GU

UIID

DEELLIIN

NEESS  FFO

OR

R  O

OPPTTIIM

MU

UM

M  EEM

MC

C  PPEER

RFFO

OR

RM

MAAN

NC

CEE

All CoolX products are designed to comply with European Normative limits (EN) for 

conducted and radiated emissions and immunity when correctly installed in a system. 

For performance levels attained, refer to 

Table 1

3

. However, power supply 

compliance with these limits is not a guarantee of system compliance. System EMC 

performance can be impacted by various system characteristics. Design 

considerations, such as PCB layout and tracking, cabling arrangements, and 

orientation of the power supply, among others, all directly contribute to the EMC 

performance of a system.
Cabling arrangements and PCB tracking layouts are the greatest contributing factors 

to system EMC performance. It is important that PCB tracks and power cables are 

arranged to minimize current carrying loops that can radiate, and to minimize loops 

Advanced Energy

®

CoolX

®

600 Modular Power Supply

57010208-00B

Safety and Product Compliance Guidelines

1‑6

Summary of Contents for Advanced Energy CoolX 600 Series

Page 1: ...o ol lX X 6 60 00 0 M Mo od du ul la ar r P Po ow we er r S Su up pp pl ly y Designers Manual S Se ep pt te em mb be er r 2 20 01 19 9 5 57 70 01 10 02 20 08 8 0 00 0B B TRC ELECTRONICS INC 1 888 612...

Page 2: ...ctives and Standards 1 7 Environmental Compliance 1 7 C Ch ha ap pt te er r 2 2 P Pr ro od du uc ct t O Ov ve er rv vi ie ew w General Description 2 1 CoolPac Options 2 1 CoolPac Operation 2 2 Auxilia...

Page 3: ...7 PMBus Communications 5 7 C Ch ha ap pt te er r 6 6 I In ns st ta al ll la at ti io on n S Se et tu up p a an nd d O Op pe er ra at ti io on n Preparing to Install the Unit 6 1 Installation Consider...

Page 4: ...Measurement of Ripple and Noise 6 24 Maintenance 6 25 To Remove CoolMod Modules 6 25 Reliability 6 25 Calculating MTBF 6 27 MTBF and Temperature 6 27 Shelf Life of Power Supplies 6 27 C Ch ha ap pt t...

Page 5: ...k module protective limits specifications 3 11 Table 3 17 Bulk module hiccup characteristics specifications 3 11 Table 3 18 Bulk module transient response specifications 3 12 Table 3 19 Bulk module st...

Page 6: ...s for bulk modules 5 9 Table 5 7 Applicable PMBus commands for dual modules 5 10 Table 5 8 Applicable PMBus commands for chassis 5 11 Table 6 1 Options for connecting AC mains input to the CoolX unit...

Page 7: ...CoolX IEC version unit dimensions side view 6 4 Figure 6 7 CoolX IEC version unit dimensions AC input view 6 4 Figure 6 8 CoolX IEC version unit dimensions top view 6 4 Figure 6 9 Three screw termina...

Page 8: ...Energy CoolX600 Series Figure 6 27 CoolMod wiring diagram for remote current setting using external resistance 6 21 Figure 6 28 Rtrim versus Iout 6 22 Figure 6 29 Foldback current limit circuit 6 22 F...

Page 9: ...o or r s se er ri io ou us s i in nj ju ur ry y D DA AN NG GE ER R i is s l li im mi it te ed d t to o t th he e m mo os st t e ex xt tr re em me e s si it tu ua at ti io on ns s WARNING W WA AR RN N...

Page 10: ...ng modules Use properly sized wires to avoid overheating and excessive voltage drop Take appropriate precautions when touching the CoolX unit after it has been operating for a period of time Due to th...

Page 11: ...CE Marking Self declaration assessed by AE Corporate Compliance EMC measurements Verified by AE Corporate Compliance SEMI guidelines Verified by AE Corporate Compliance Safety Approvals CoolX units a...

Page 12: ...D The relevant European standard for the CX06S model is EN 60950 1 2nd Edition information technology and 62368 1 Edition 2 The relevant European standard for the CS06M model is EN60601 1 3rd Edition...

Page 13: ...characteristics of CoolX unit under load conditions P Pa ar ra am me et te er r C Co on nd di it ti io on ns s D De es sc cr ri ip pt ti io on ns s C Cr ri it te er ri ia a Radiated emissions EN55011...

Page 14: ...rmal operation D During the test loss of function that is not recoverable occurs A AD DD DI IT TI IO ON NA AL L E EM MI I C CH HA AR RA AC CT TE ER RI IZ ZA AT TI IO ON N CoolX units are compliant wit...

Page 15: ...er to the EU Declaration of Conformity for this unit The Declaration of Conformity might also include a supplementary section covering compliance to non EU regulatory requirements and or industry stan...

Page 16: ...CS INC 1 888 612 9514 www trcelectronics com Designers Manual Advanced Energy CoolX600 Series ECHA that are contained in this product at concentrations greater than 0 1 by weight Advanced Energy CoolX...

Page 17: ...to increase output voltage subject to staying within isolation ratings and giving due consideration to any SELV requirements You can connect CoolPac chassis in parallel for higher power and N 1 redund...

Page 18: ...lated bias supply voltage Option B 5 V auxiliary voltage The chassis includes a 5 V 4 7 A isolated bias supply voltage Option C Conformal coating The CoolPac chassis has a conformal coating for harsh...

Page 19: ...ring displays For system housekeeping In control circuits As an additional output voltage Important The negative of the auxiliary Vo is connected to the common of the system signal connector J1 AUXILI...

Page 20: ...al and then through an EMI filter designed to meet EN55022 Class B Some applications might require an external ferrite on cabling to meet Class B radiated EMI Contact AE Global Services for recommenda...

Page 21: ...screws Four mounting holes on base Two mounting holes on each side The CoolX unit can be mounted on its base or on its side It can also be mounted on the Excelsys DIN rail accessory Connectors AC DC...

Page 22: ...I IO ON NS S The nominal values of the following specifications apply when the unit operates at 25 C 77 F with nominal output voltage T Ta ab bl le e 3 3 2 2 Electrical specifications D De es sc cr ri...

Page 23: ...A 4 7 A Output capacitive load maximum 1 000 F Output overcurrent protection 110 to 140 hiccup condition Short circuit protection Yes autorecovery Leakage Currents at mains voltage 264 VAC 60 Hz Type...

Page 24: ...15 105 130 180 CmC 24 15 28 105 125 105 135 8 33 105 130 200 CmD 48 28 58 105 125 103 115 4 17 105 150 200 Each type of CoolMod module has unique specifications The following figures and tables detail...

Page 25: ...imum 180 kHz 180 kHz 180 kHz 180 kHz Nominal Typical 240 kHz 240 kHz 240 kHz 240 kHz Maximum 450 kHz 450 kHz 450 kHz 450 kHz T Ta ab bl le e 3 3 6 6 Standard module regulation specifications P Pa ar r...

Page 26: ...nal Typical 130 W 220 5 W 232 W 230 W Maximum 137 W 234 W 260 W 260 W Overvoltage protection shutdown autorecovery Minimum 6 8 V 17 V 32 V 60 V Nominal Typical 8 V 19 8 V 35 V 62 2 V Maximum 9 V 21 V...

Page 27: ...V 7 2 V 14 3 V Nominal Typical 1 4 V 4 2 V 8 1 V 16 2 V Minimum 2 0 V 4 9 V 9 6 V 19 8 V Recovery time Recovery time Positive voltage deviation Negative voltage deviation F Fi ig gu ur re e 3 3 3 3 M...

Page 28: ...Vout AC In F Fi ig gu ur re e 3 3 4 4 Module startup shutdown timing T Ta ab bl le e 3 3 1 10 0 Standard module startup shutdown timing specifications P Pa ar ra am me et te er r V Va al lu ue e T Ty...

Page 29: ...0 35 ms 0 35 ms 0 35 ms 0 35 ms Maximum 3 ms 3 ms 3 ms 3 ms Bulk Module Specifications Bulk modules include CmE and CmF modules The following tables provide specifications for bulk modules T Ta ab bl...

Page 30: ...ading Maximum 10 mF 2 5 mF For an illustration of the module ripple and noise see Figure 3 1 on page 3 5 T Ta ab bl le e 3 3 1 14 4 Bulk module ripple and noise specifications P Pa ar ra am me et te e...

Page 31: ...er 5 hiccup cycles Maximum 5 A 2 5 A Power limit hiccup autorecovery Minimum 615 W 615 W Nominal Typical 695 W 670 W Maximum 755 W 755 W Overvoltage protection shutdown autorecovery Minimum 29 V 45 5...

Page 32: ...000 s 1000 s In Figure 3 4 on page 3 8 t1 is the turn on delay and t2 is the hold up Table 3 19 contains t1 and t2 values for each type of bulk module T Ta ab bl le e 3 3 1 19 9 Bulk module startup sh...

Page 33: ...dj ju us st t V Vs se et t V V O OV VP P T Tr ra ac ck ki in ng g o of f V Vs se et t O OV VP P L La at tc ch hi in ng g o of f V Vm ma ax x M Ma ax xi im mu um m C Cu ur rr re en nt t I Im ma ax x A...

Page 34: ...se specifications P Pa ar ra am me et te er r V Va al lu ue e T Ty yp pe e C Cm mG G V V1 1 a an nd d V V2 2 C Cm mH H V V1 1 C Cm mH H V V2 2 Output ripple and noise 20 MHz bandwidth Nominal Typical...

Page 35: ...dule transient response see Figure 3 3 on page 3 7 T Ta ab bl le e 3 3 2 26 6 Dual module transient response specifications 25 to 75 load change P Pa ar ra am me et te er r V Va al lu ue e T Ty yp pe...

Page 36: ...Specifications Wide trim modules include CmM CmN CmP and CmQ modules The following tables provide specifications for wide trim modules T Ta ab bl le e 3 3 2 29 9 General wide trim module outputs M Mo...

Page 37: ...mF 4 7 mF 1 Full dynamic specifications might not be met at full load when you trim a CmM module above 13 V in a CoolX unit 2 Maximum output current is derated by 5 when a module is used in parallel 3...

Page 38: ...T Ta ab bl le e 3 3 3 33 3 Wide trim module protective limits specifications P Pa ar ra am me et te er r V Va al lu ue e T Ty yp pe e C Cm mN N C Cm mM M C Cm mP P C Cm mQ Q Current limit constant cu...

Page 39: ...0 ms 1100 ms Short circuit hiccup level Minimum 0 6 V 0 6 V 0 6 V 1 1 V Minimum 0 9 V 0 9 V 0 9 V 2 0 V For an illustration of the module transient response see Figure 3 3 on page 3 7 T Ta ab bl le e...

Page 40: ...e timing specifications P Pa ar ra am me et te er r V Va al lu ue e T Ty yp pe e A Al ll l M Mo od du ul le es s Enable delay t1 enable to Vout Nominal Typical 8 5 ms Maximum 10 ms Rise time from 10 t...

Page 41: ...Climatic specifications D De es sc cr ri ip pt ti io on n S Sp pe ec ci if fi ic ca at ti io on n External Ambient Temperature Operating 20 C to 40 C 4 F to 104 F Operates to specification below 20 C...

Page 42: ...ed for your power requirements Refer to Electrical Specifications on page 3 2 for CoolPac specifications Once you have determined the appropriate configuration for your application use CoolX Configura...

Page 43: ...um mb be er r D Di ig gi it t F Fe ea at tu ur re e O Op pt ti io on ns s a an nd d D De es sc cr ri ip pt ti io on ns s 1 Reserved C 2 Reserved X 3 Reserved 0 4 Reserved 6 5 CoolPac type S Standard I...

Page 44: ...ge 13 Frame type Not used or Standard open framed L Covered 14 Reserved Not included in configuration order Specifying Modules in the Part Number Digits 6 9 in a CoolX part number specify the modules...

Page 45: ...specifies which part number digit corresponds to which chassis slot The examples in Selecting and Ordering a Configured CoolX Unit further demonstrate how to specify modules in a CoolX unit part numb...

Page 46: ...150 A leakage current Solution CoolX part number CX06M ABC0 P4B specifies the following product CX06M 600 W IEC60601 1 approved Slot 1 CmA 5 V 10 A module Slot 2 CmB 12 V 15 A module Slot 3 CmC 24 V...

Page 47: ...me en nt t 1 Common 2 SCL PMBus CLK 3 Control 4 SDA PMBus DATA 5 PG Global 6 NU not used or no connection 7 OTP 8 AC Fail CoolPac Open Collector Driving Common Logic Levels Each CoolPac logic output...

Page 48: ...Lo og gi ic c V Vo ol lt ta ag ge e V Vo ol lt t L Lo og gi ic c R R1 1 k k R R2 2 k k V Vh hi ig gh h V V V Vl lo ow w V V I Is si in nk k M Ma ax x m mA A 12 V 12 12 Open 12 0 4 12 12 V 5 10 7 4 9 0...

Page 49: ...ble Inhibit Control You can enable or inhibit all module outputs simultaneously by using the control pin input on the J1005 system signal connector between pin 3 control and pin 1 common Under normal...

Page 50: ...for driving logic level circuits with open collector signal outputs M MO OD DU UL LE E S SI IG GN NA AL LS S Each module has the following discrete controls Module Enable Inhibit CoolMod Power Good S...

Page 51: ...in 3 control and pin 1 common of the J1005 system signal connector Advanced Energy recommends a Harwin M22 1900005 2 mm jumper socket for the J1011 connector F Fi ig gu ur re e 5 5 4 4 PMBus address h...

Page 52: ...GND 3k F Fi ig gu ur re e 5 5 5 5 Dual module enable inhibit wiring diagram Applying a signal voltage to the inhibit pins disables the channel The specifications for this signal are detailed in the f...

Page 53: ...al module POWER GOOD wiring diagram The POWER GOOD signal is the unbiased open collector of an optocoupler that is available on the module signal connector J1 via the collector on the positive PG pin...

Page 54: ...ement of the selected paged module Accuracy 4 Module Resolution mA CmA 40 CmB 29 CmC 16 CmD 8 CmM TBD CmN TBD CmP TBD CmQ TBD READ_TEMPERATURE_1 0x8D Returns the temperature measurement of the selecte...

Page 55: ...s the current limit of the selected paged module to the commanded value When read this command returns the last ILIMIT_TRIM value sent to the selected paged module This command is not compatible with...

Page 56: ...aged module VOUT_COMMAND 0x21 Sets the output voltage of the selected paged module to the commanded value When read this command returns the last VOUT_COMMAND value sent to the selected module ILIMIT_...

Page 57: ...an nd d D De es sc cr ri ip pt ti io on n PAGE 0x00 Selects which module the subsequent commands will affect When read this command returns the currently selected paged module number OPERATION 0x01 E...

Page 58: ...penetration depth is 2 mm 0 08 DIN rail mounting is also possible using the Excelsys DIN rail mounting bracket Avoid excessive bending of output power cables after they are connected to the modules Fo...

Page 59: ...CoolX600 Series 39 mm 1 5 114 mm 4 5 24 mm 0 9 F Fi ig gu ur re e 6 6 1 1 CoolX unit dimensions DC outputs view 162 mm 6 4 6 mm 0 2 39 mm 1 5 10 mm 0 4 3 mm 0 1 216 mm 8 5 F Fi ig gu ur re e 6 6 2 2 C...

Page 60: ...ions bottom view I IE EC C U UN NI IT T D DI IM ME EN NS SI IO ON NA AL L D DR RA AW WI IN NG GS S The CoolX mechanical outlines for the IEC version of the unit follow You can download full 3D and STE...

Page 61: ...th sides 162 mm 6 4 6 mm 0 2 39 mm 1 5 10 mm 0 4 3 mm 0 1 216 mm 8 5 F Fi ig gu ur re e 6 6 6 6 CoolX IEC version unit dimensions side view 27 mm 1 1 26 mm 1 114 mm 4 5 41 mm 1 6 F Fi ig gu ur re e 6...

Page 62: ...9 9 Three screw terminal block Earth Live Neutral F Fi ig gu ur re e 6 6 1 10 0 Optional IEC320 inlet terminal T Ta ab bl le e 6 6 1 1 Options for connecting AC mains input to the CoolX unit I In np...

Page 63: ...OL LM MO OD D O OU UT TP PU UT T P PO OW WE ER R A AN ND D S SE EN NS SE E C CO ON NN NE EC CT TO OR RS S Each standard and wide trim module DC output has power terminals J1 and J2 and a sense connect...

Page 64: ...CO ON NN NE EC CT TO OR RS S Dual modules have a signal connector J1 and a dual power terminal J2 J J1 1 Inhibit V1 J J1 1 PG V1 J J1 1 Inhibit V2 J J1 1 PG V2 J J1 1 Inhibit V1 J J1 1 PG V1 J J1 1 In...

Page 65: ...ON Refer to Global Signals on page 5 1 for J1005 system signal connector information T Ta ab bl le e 6 6 4 4 J1005 system signal connector types C Co on nn ne ec ct to or r C Co on nn ne ec ct to or r...

Page 66: ...g Molex 51110 0650 or locking and polarizing Molex 51110 0650 Crimp terminal Molex p n 50394 I IN NS ST TA AL LL LI IN NG G T TH HE E U UN NI IT T To Install CoolMod Modules 1 Plug one module into the...

Page 67: ...load Special series connection links can be fitted to modules to reduce wiring complexity These links can be specified and fitted by the installer or added at the factory Important You can connect dua...

Page 68: ...6 6 7 7 Standard and wide trim module parallel voltage tolerances M Mo od du ul le e P Pa ar ra al ll le el l V Vo ol lt ta ag ge e T To ol le er ra an nc ce e m mV V CmA 10 CmB 10 CmC 10 CmD 20 CmM...

Page 69: ...To Parallel Connect Bulk Module Outputs 1 Enable current sharing by adding an LK1 jumper on the J1017 connector of a module The J1017 connector is located on the communication board of the chassis J10...

Page 70: ...by using a single control voltage Mounting the CoolPac There are three ways to mount the CoolPac Base plate mounting Use the four mounting holes on the base of the power supply Refer to the mechanica...

Page 71: ...uts can be sequenced using the enable function in order to allow controlled start up if required The following table contains the maximum startup delays for all modules T Ta ab bl le e 6 6 8 8 Startup...

Page 72: ...its maximum power as per the module specification tables The following optional additions to the CoolX unit can affect the optimum temperature range for normal operation EXTERNAL SYSTEM COOLING FANS I...

Page 73: ...he onboard potentiometer Refer to Onboard Potentiometer Use the Vtrim pin of the output signal connector J1001 to J1004 Refer to Remote Voltage Adjustment Using External Voltage and Remote Voltage Adj...

Page 74: ...g external voltage The Vtrim voltage required for your desired output voltage can be calculated using the following formula and table Vtrim Vout F K T Ta ab bl le e 6 6 9 9 K and F values for calculat...

Page 75: ...6 2 22 2 CoolMod wiring diagram for remote voltage setting using external resistance You can calculate the Rtrim resistance required for your desired output voltage by using Table 6 9 and the followin...

Page 76: ...it The default current limit characteristic is straight line current limit Simple external application circuits can be used to achieve programmable foldback current and user programmable reduced curre...

Page 77: ...trim return Pin 1 or Pin 3 5 V F Fi ig gu ur re e 6 6 2 25 5 CoolMod wiring diagram for remote current setting using external voltage The Itrim voltage required for your desired current limit can be c...

Page 78: ...esistor Rtrim across the output signal connector pins pin 5 Vtrim and pin 1 common Important Current limit adjustment is not available on dual modules 10k 100 nF Comms Board uController 5 6 Module 47k...

Page 79: ...Limit Programming Foldback current limit requires the common pin of the output connector to be tied to the V output connector of the module the common pin is also Vo of the auxiliary voltage Foldback...

Page 80: ...ted by the fixed OVP at high output voltages The fixed OVP level is fixed relative to Vmax and activates between 125 and 160 of the maximum output voltage This OVP is latching and can only be reset by...

Page 81: ...ute the sensing leads to prevent pickup which might appear as ripple on the output Never disconnect the output power rail with the sensing still connected to the load In certain applications where the...

Page 82: ...tional details about how to measure and reduce output ripple and noise M MA AI IN NT TE EN NA AN NC CE E To Remove CoolMod Modules Important CoolX units do not have user serviceable components the uni...

Page 83: ...e the first signs of wear appear and failures become more frequent The lifetime of a unit is generally defined as the time when the failure rate increases to five times the statistical rate of the fla...

Page 84: ...e following values are preliminary Module 0 52 failures per million hours Chassis 1 08 failures per million hours Example CX06S chassis FPMH 1 08 CmA CmB CmC CmD module FPMH 0 52 each Total FPMH 1 08...

Page 85: ...tor which results in additional heating of the component and has a direct impact on reliability According to published research the commencement of this chemical reaction can occur after a two year pe...

Page 86: ...identify the causes of high frequency noise Is the noise conducted or radiated If changing the position of the power supply or screening improves performance the noise is likely radiated Refer to EMC...

Page 87: ...Excelsys to get the correct shipping address T Ta ab bl le e 7 7 1 1 Contact information O Of ff fi ic ce e C Co on nt ta ac ct t Excelsys Technologies Ltd Address 27 Eastgate Drive Eastgate Business...

Page 88: ...startup and shutdown 6 14 CoolPac global signals 5 1 mounting 6 13 open collector 5 1 options 2 1 CoolPac chassis global enable inhibit control 5 3 Global Power Good signal 5 3 operation 2 2 current...

Page 89: ...t time 6 13 measurement of ripple and noise 6 24 normal 6 14 parallel connection of bulk CoolMod outputs 6 12 parallel connection of CoolMod outputs 6 10 series connection of module outputs 6 9 theory...

Page 90: ...standards 1 7 straight line current limit 6 19 symbols in user manual 1 1 on unit 1 2 T T theory of operation 2 3 U U unit compliance 1 3 icons and symbols used 1 2 preparing to install 6 1 unit desc...

Reviews: