You can only use a bulk module in slot 4 of a chassis. A bulk module takes up three
slots in a chassis; the module is placed in slot 4 and covers slot 2 and slot 3. When
you use a bulk module, you can only place one other module in the chassis. The other
module must be a standard, dual, or wide-trim module placed in slot 1.
When specifying a bulk module in a CoolX unit part number, use the third letter of
the type of module (for example, "E" for a CmE module) in the ninth digit of the part
number. In addition to specifying the module type in the ninth digit, include hash
symbols/pound signs (the "#" character) in the seventh and eighth digits of the part
number. The pound sign indicates that slot 2 and slot 3 cannot be used because the
module in slot 4 is a bulk module.
Table 4
‑
1
on page 4
‑
2 specifies which part number
digit corresponds to which chassis slot.
The examples in
“Selecting and Ordering a Configured CoolX Unit”
further
demonstrate how to specify modules in a CoolX unit part number.
Selecting and Ordering a Configured CoolX Unit
Configured CoolX power supplies can be specified and ordered using the part
numbering system previously described. The CoolX unit will be assembled as
specified by the part number.
C
CO
ON
NFFIIG
GU
UR
RAATTIIO
ON
N EEXXAAM
MPPLLEE 11
Required power supply: 100 VAC to 240 VAC input, IEC 60950 and IEC 62368
approved
Outputs: 5 V/10 A, 24 V/6 A, 48 V/4 A
Auxiliary bias supply 12 V/1 A
Solution: CoolX part number CX06S-ACD0-N-A specifies the following product:
• CX06S—600 W IEC60950 approved
• Slot 1: CmA, 5 V/21 A module
• Slot 2: CmC, 24 V/8.33 A module
• Slot 3: CmD, 48 V/4.17 A module
• Slot 4: Empty
• Option N: Nominal output voltage settings
• Option A: 12 V/1.97 A bias supply voltage
C
CO
ON
NFFIIG
GU
UR
RAATTIIO
ON
N EEXXAAM
MPPLLEE 22
Required power supply: 100 VAC to 240 VAC input, IEC 60601-1 3rd Edition
approved
Outputs: 5 V/10 A, 12 V/5 A, 24 V/11 A
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Configuration
4‑4