Advanced Energy CoolX600 Series
• Earth leakage current of < 300 μA
The following table describes alternate CoolPac options:
TTaabbllee 22‑‑22.. CoolPac options
O
Oppttiioonn
D
Deessccrriippttiioonn
Option 1: Input connector
The AC mains connector is an IEC320
inlet.
Option 4: Low leakage current 150 μA The leakage current is < 150 μA, meant for
medical applications using two or more
power supplies or containing additional
parts that contribute to the system earth
leakage current. This ensures that system
earth leakage current does not exceed
levels defined in IEC60601 3rd Edition.
Option A: 12 V auxiliary voltage
The chassis includes a 12 V/1.97 A
isolated bias supply voltage.
Option B: 5 V auxiliary voltage
The chassis includes a 5 V/4.7 A isolated
bias supply voltage.
Option C: Conformal coating
The CoolPac chassis has a conformal
coating for harsh environments and MIL-
COTS applications.
Option L: Enclosed frame
This chassis has an enclosed frame with a
lid.
CoolPac Operation
The CoolPac chassis provides the front end input power to each module. The
CoolPac chassis operates off 85 VAC to 264 VAC, 47 Hz to 63 Hz and can withstand
300 VAC input voltage for up to 5 sec. The chassis can operate off up to 440 Hz, but
operating off > 63 Hz puts the unit outside the unit safety ratings and approvals.
Contact AE Global Services before operating the unit off > 63 Hz.
The chassis can also operate off DC inputs of 125 VDC to 300 VDC. However,
operation with DC inputs is not within unit safety ratings and approvals. Contact
AE Global Services before operating the unit with DC inputs.
Table 2
‑
1
details each CoolPac version.
Advanced Energy
®
CoolX
®
600 Modular Power Supply
57010208-00B
Product Overview
2‑2