www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
IG0108EN V0.1 08/20
P. 25 of 29
4. CONFIGURATION
4.1 Luminaire Addressing and Control
The ProPoint Vista 200W luminaire utilizes 4 DMX channels for the RGBW unit, and 1 DMX channel for the Static
White units and for the ProPoint Vista 400W, utilizes 8 DMX channels for the RGBW unit, and 2 DMX channel for
the Static White units.
The ProPoint Vista luminaires are shipped with a default DMX address of 001. For installations where independent
control of luminaires is required, the DMX address will need to be modified using a controller that supports Remote
Device Management (RDM).
•
Connect an RDM capable control device to the DMX line ahead of the first luminaire.
•
Enable RDM discovery per the instructions of the controller manufacturer.
•
The controller will discover available ProPoint luminaires. These luminaires can be identified by the prefix 16DC
in each unit’s UID.
•
Using the RDM identify function, locate a single unit in the installation. The associated luminaire will flash.
•
Note the physical location of the flashing unit and then disable the identify function.
•
Determine the desired address for the identified luminaire and enter it in the address field of the RDM controller.
•
Continue the above process until all units have been addressed.
•
Record the UID data and associated addresses at the end of this document.
•
Test each luminaire to verify correct addressing prior to completing installation.
ProPoint Power-Up and Loss of Data Behavior
The ProPoint Vista luminaire will exhibit the following behavior upon power-up and loss of DMX data:
Power-Up with no DMX data present
Luminaire will illuminate at full power
Power-Up with DMX data present
Luminaire will respond based on the DMX values being received
Loss of DMX data
Luminaire will hold the last valid DMX values received until a power cycle or
until DMX is restored.
DMX Channel Functions
RGBW Unit
DMX Channel
Function
1
Red Intensity
2
Green Intensity
3
Blue Intensity
4
White Intensity