FIG.19: System Diagram – SYMPL DMX/e:pix node
Installation engineer should use
appropriate plugs for outdoor
connection.
End cap
Ethernet Switch
SYMPL Core S
Mains AC ~
Last dot of string
Indoor
Outdoor
Cable C
Cable B
Cable A
RJ45 Male Connector Housing IP67
To construct a longer data cable,
use outdoor data cable with RJ45
housing.
Smart
Junction
SYMPL DMX Node
e:net
connection
DMX/e:pix connection
To other DMX Nodes
DMX/e:pix connection
Pin 3: GND
RJ45 Plug
Pin 2: DMX+
Pin 1: DMX–
Allegro Dot Pixel Distributor
LED Engine 240W/185W/100W 30V Outdoor
Outdoor cable specification:
CAT-5e UTP/FTP
PVC jacket; UV resistant
Outer diameter 6mm/0.24”
Filled type
(The warranty will void if in use
cable is not follow the
specification of outdoor cable)
X-lock Lead Cable (5m/10m)
Cable A
Cable B
TX Connect Data Bridge
Indoor/Outdoor Cable (5m)
Maximum: 50m
TX Connect Data Outdoor Cable
0.6m/2ft or 3m/10ft available
Cable C