
www.traxontechnologies.com
©2019 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U.
PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
12/19 V2.0
18 of 23
3. SYSTEM CONFIGURATION
FIG.18: System Diagram – e:net connection
Installation engineer should use
appropriate plugs for outdoor
connection.
Allegro Dot Pixel Distributor
End cap
Ethernet Switch
SYMPL Core S
Mains AC ~
Last dot of string
Indoor
Outdoor
Cable C
Cable B
Cable A
RJ45 Male Connector Housing IP67
To other distributor chain
To construct a longer data cable,
use outdoor data cable with RJ45
housing.
Smart
Junction
LED Engine 240W/185W/100W 30V Outdoor
e:net connection
DMX/e:pix connection
X-lock Lead Cable (5m/10m)
Cable A
Cable B
TX Connect Data Bridge
Indoor/Outdoor Cable (5m)
Maximum: 50m
TX Connect Data Outdoor Cable
0.6m/2ft or 3m/10ft available
Cable C
Outdoor cable specification:
CAT-5e UTP/FTP
PVC jacket; UV resistant
Outer diameter 6mm/0.24”
Filled type
(The warranty will void if in use
cable is not follow the
specification of outdoor cable)