2.2.3
Requirements Of Cable Bending And Twisting
Please take EXTRA precautions before bending or twisting Allegro Dot M/L cable.X-lock Lead
Cable must NOT be bent below the Minimum Bending Radius (4x Cable Diameter) and the
Non-Bendable Length of 50mm near the connector end or near the cable overmold MUST be
adhered to.
FIG.10: Minimum Cable Bending and Non-Bendable Length Requirement
D
Ø9.5mm/0.37”
(Non-Bendable Length)
240mm/9.4”
≥
4D
(Minimum Bending Radius)
38mm/1.50”
20mm/0.79”
D
Ø9.5mm/0.37”
50mm/1.97”
(Minimum Bending Radius)
38mm/1.50”
≥
4D
The flat Allegro Dot M/L Cable must NOT be bent/twisted below 20mm (0.79”) from edge of
Allegro Dot housing (Non-Bendable/Non-Twistable Length).
Twisting the flat cable is NOT recommended. If twisting is necessary for installation, please
adhere to the above Non-Twistable Length and ensure the mounting pitch is greater than or
equal to 75% of the normal Allegro Dot to Allegro Dot pitch. The middle part of the cable must
be secured to the mounting fixture with a cable tie (see “2.3 On-Site Installation” on page
15 and FIG.17 on page 17). Ensure no damage is generated on the cable.
FIG.11: Minimum Clearance
20mm/0.79”
Minimum clearance
from dot
Non-Bendable/
Non-Twistable Length
NOTE: Water ingress incurred due to excess cable bending/twisting will not be under