![Travis Industries Xtreme 6020 Installation Manual Download Page 6](http://html.mh-extra.com/html/travis-industries/xtreme-6020/xtreme-6020_installation-manual_1154149006.webp)
6
Features and Specifications
© Travis Industries
4140717
100-01351
Installation Options
Residential or Commercial Installations
Raised or Floor Placement
Internal
or
External Chase
Horizontal or Vertical Vent
Bedroom
Approved
BTU Specifications
Natural Gas
Propane
Maximum BTU Input Per Hour
90,000
90,000
Dimensions
(a) Measurement to Cover Box (back edge)
(b) Front Edge (front edge of framing
(c) Framing Set-Back
(d) Facing Guide (protrudes to the front of drywall)
3-7/8" 98mm
62" 1575mm
a
b
c
d
1-7/8" 48mm
56-1/2" 1435mm
54-1/4"
1378mm
23-1/2"
597mm
11-1/2" 292mm
Left
Front
Back
Right
12"
305mm
21-3/4"
552mm