Overview
This manual details the installation requirements for
the Xtreme 6020 fireplace. For operating and
maintenance instructions, refer to the Owner's
Manual (part # 100-01247).
Listing Details
This appliance was listed by Intertek (Warnock
Hersey) to ANSI Z21.50b-2009 / CSA 2.22b-2009 -
report # 3183426 The listing label is chained to the
appliance near the glass frame. A copy is shown to
the right.
IAS (ICBO) Approval
This appliance was listed by Intertek (Warnock
Hersey) - IAS # TL271.
Massachusetts Approval
This manual has been submitted to the
Massachusetts Board of State Examiners of
Plumbers and Gas Fitters
National Fireplace Institute
Report No. 100866534PRT
-001
Control No. 4000515
V
e
nted Gas Fireplace Heater
Xtreme 6020 L.P
.
Xtreme 6020 N.G.
Tested to:
ANSI Z21.50b-2009/CSA
2.22b-2009 “V
ented Gas Fireplace”
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas
Code,
ANSI Z223.1/NFP
A
54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This vented gas fireplace heater is equipped at the factory for use with gas fuel marked above. No conversion is
allowed.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying
appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s
installation instructions. See owner
’s
manual for approved brands of venting.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the owner
’s
information manual provided with this appliance. For assistance or additional
information consult a qualified installer
, service agency or the gas supplier
.
VENTED GAS FIREPLACE HEA
T
ER - NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles
Fireplace to
Adjacent W
all
W
o
od Floor Beneath Fireplace
Back to Enclosure
3” (76mm)
0” (0mm)
0” (0mm)
To
p to Enclosure
Sides to Enclosure
Base of Fireplace to a Mantel
37.5” (953mm)
3” (76mm)
See Owner
’s
Manual
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
L.P
.
11
”
13”
11
”
N.G.
5.5”
7”
3.5”
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
Orifice Size - Center (DMS)
Orifice Size - Sides (DMS)
L.P
.
90,000
45,649
#46
#54
N.G.
90,000
57,896
#25
#46
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See owner
’s
manual for information on making these changes.
2014
2015
2013
Feb.
Mar
.
Jan.
May
Jun.
Apr
.
Aug.
Sep.
Jul.
Nov
.
Dec.
Oct.
MANUF
ACTURE DA
TE:
W
ARNING: Failure to install this appliance per the manufacturer
’s
instructions or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury
.
4800 Harbour Pointe Blvd. SW
Mukilteo, W
A
98275
Manufactured by:
www
.travisproducts.com
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done
by a licensed or qualified service person.