8/8
6-1620026 rev.P4 22/02/2016
1
2
3
8
7
6
5
4
RELA
Y 1
RELA
Y 2
P2
P1
P3
PO
TENTIOMETER
DISPLA
Y
OUT1
OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Door operator
Electric Strike
Transmitter
12-24 Vac/Vdc
Power for Strike
PUSH
TO OPEN
13
14
7380 S. Eastern Ave, Ste 124-320
Las Vegas, NV 89123
(866) 975-0101 - (866) 975-0404 Fax
www.transmittersolutions.com
NOTICE
Any changes or modification to the equipment not expressly approved by Transmitter Solutions could void the manufacturer’s warranty and the
user’s authority to operate this product.
WARRANTY
The warranty period of Transmitter Solutions receiver is twenty-four (24) months. This warranty shall begin on the date the receiver is
manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product
does not operate correctly due to a defective component. This warranty does not extend to (a) the receiver case, which can be damaged by
conditions outside the control of Transmitter Solutions.
WARRANTY
MODE 6 - LATCHED MODE OPTION (2)
MODE 6 - Latched mode 2
You must program the transmitters on the relay 1.
The transmitter activates the relay 1 for the
TON1
time. Then, after the
TDLY
time, it activates the relay 2.
To disable the relay 2, use again the transmitter.
PROGRAMMING - STEP BY STEP
1.
Press briefly the P1 button. The display shows
rad1
.
2. Press the button of the transmitter. The display shows
done
.
3.
To quit, press briefly the P1 button.
4.
To enter the menu, press briefly the P3 button.
5. Set the item
funCt
to
6
.
6.
Press briefly the P3 button.
7. Set the
ton1
time to the desired value.
8.
Press briefly the P3 button.
9.
Press briefly the P3 button.
10. Set the
tdLY
time to the desired value.
11.
Press briefly the P3 button.
12.
Press briefly the P3 button.