4/8
6-1620026 rev.P4 22/02/2016
1
2
3
8
7
6
5
4
RELA
Y 1
RELA
Y 2
P2
P1
P3
PO
TENTIOMETER
DISPLA
Y
OUT1
OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Door operator
Electric Strike
Transmitter
Transmitter
12-24 Vac/Vdc
Power for Strike
PUSH
TO OPEN
PUSH
TO OPEN
9
MODE 2 - SWITCHING NETWORK
MODE 2 - Switching network
You must program the transmitters on the relay 1.
The transmitters activate the relay 1 for the
TON1
time. Then, after the
TDLY
time, they activate the relay 2 for the
TON2
time.
PROGRAMMING - STEP BY STEP
1.
Press briefly the P1 button. The display shows
rad1
.
2. Press the button of the transmitter #1. The display shows
done
.
3.
To quit, press briefly the P1 button.
4.
To enter the menu, press briefly the P3 button.
5. Set the item
funCt
to
2
.
6.
Press briefly the P3 button.
7. Set the
ton1
time to the desired value.
8.
Press briefly the P3 button.
9. Set the
ton2
time to the desired value.
10.
Press briefly the P3 button.
11. Set the
tdLY
time to the desired value.
12.
Press briefly the P3 button.
13.