background image

2/8

6-1620026             rev.P4              22/02/2016

5

4

While the receiver is in standby the display shows the selected mode of functioning (

mode1

mode2

mode3

mode4

mode5

mode6

). During the process 

of a timed command, the display blinks. During a step by step command, as in mode 5 and 6, the display does not blink.

To enter the menu, press briefly the P3 button.
Press briefly the P3 button to move inside the items of the menu and use the POTENTIOMETER

 to change the parameters.

The receiver saves the parameters when it quits the menu.

MENU

DESCRIPTION

SELECTABLE 

VALUES

min-max

DEFAULT

UNIT

fUNCT

FUNCTION

Menu for the selection of the functioning mode:

1

 - Dual independent outputs.

2

 - Switching network.

3

 - Vestibule sequencing, type 1.

4

 - Vestibule sequencing, type 2.

5

 - Latched mode 1.

6

 - Latched mode 2.

1 - 6

1

-

Ton1

ACTIVATION TIME FOR RELAY 1

1 - 60

1

s

Ton2

ACTIVATION TIME FOR RELAY 2

1 - 60

1

s

TdLy

DELAY TIME BETWEEN THE ACTIVATION OF THE TWO RELAYS

1 - 60

1

s

Power

POWER OF THE SIGNAL

The display shows the quality of the transmission signal.

BAD - BEST

-

-

5.1 - FUNCTION
By accessing the item 

funct

 it is possible to set the functioning mode:

1

 - Dual independent  outputs: operates as a two channels receiver.

2

 - Switching network: also known as a switching network or make/break relay, use this mode with a door operator & lock.

3

 - Vestibule sequencing, type 1: to be selected if you want to sequence two doors in both directions, using just one receiver (requires two 

conductors to the second door).

4

 - Vestibule sequencing, type 2: to be selected if you want to sequence two doors in both directions, using two receivers and no wiring between operators.

5

 - Latched mode 1: access control application. A transmitter signal programmed into the channel 1 will latch relay 1. While the relay 1 is latched, a 

transmitter programmed into the channel 2 will activate the relay 2. When the channel 1 is in the off state, the receiver will ignore the channel 2 inputs.

6

 - Latched mode 2: freight door application. In this mode a transmitter will active the relay 1 for an adjustable time, then latch the relay 2. The 

relay 2 stays latched until another transmitter signal is received, then drops out immediately.

5.2 - ACTIVATION TIME FOR RELAY 1
By accessing the item 

ton1

 it is possible to select the activation time of the relay 1. Use the 

POTENTIOMETER

 to set a value between 1 and 60 s.

5.3 - ACTIVATION TIME FOR RELAY 2
By accessing the item 

ton2

 it is possible to select the activation time of the relay 2. Use the 

POTENTIOMETER

 to set a value between 1 and 60 s.

5.4 - DELAY TIME BETWEEN THE ACTIVATION OF THE TWO RELAYS
By accessing the item 

tdLY

 it is possible to select the delay time between the activation of the two relays. Use the 

POTENTIOMETER

 to set a value 

between 1 and 60 s.

5.5 - POWER OF THE SIGNAL
By accessing the item 

power

 it is possible to verify the quality of the transmission signal of a transmitter already memorized.

When the display shows 

-----

, press the button of the transmitter. The display can show:

• 

 

bad

: the signal quality is very low. 

With a low signal quality it is suggested that you move the receiver to improve the signal. 

• 

 

g

ood

: the signal quality is good.

• 

 

best

: the signal quality is very high.

MENU

It is possible to select the code type in use on the receiver.

Follow this procedure for the selection:
1.  Switch off the power supply.
2.  Press and hold at the same moment all the buttons of the receiver. After 5 seconds, OUT1 and OUT2 leds blink:

• 

3 times if the Rolling Code is enable. The display shows 

BiroL

.

• 

6 times if the Sawn Rolling Code is enable (Transmitter Solutions 433 MHz + KEELOQ

®

 HCS300-301 compatible). The display shows 

sawn

.

When the Sawn Rolling Code is set, a point appears on the display between the 3rd and the 4th digit.

CODE TYPE SELECTION

1.  Press and hold the P2 button. 
2.  When the display shows 

C2CLr

 and the OUT2 led blinks fast for 3s, release the button. The transmitters have been deleted from the relay 2.

To delete a single trasmitter from the memory, follow the following steps:
1.  Press the P1 or P2 button. The display shows 

rad1

 or 

rad2

.

2.  Press the 1st key and the hidden button at the same moment of the transmitter that you want to erase.
3.  When the display shows 

CLEAR

, release the buttons. The transmitter has been deleted from the memory.

Summary of Contents for HIVE-DX

Page 1: ...rized Note if the transmitter is already memorized the display shows fnd1 associated to the 1st relay or fnd2 associated to the 2nd relay and then it exits from the process ATTENTION aprogrammedbuttoncannotbememorizedinboththerelays Tochangetheassociatedrelay removethetransmitterassociated to the button from the memory and then make again the learning process NOTE the programmed button of the tran...

Page 2: ...e relay 2 The relay 2 stays latched until another transmitter signal is received then drops out immediately 5 2 ACTIVATION TIME FOR RELAY 1 By accessing the item ton1 it is possible to select the activation time of the relay 1 Use the POTENTIOMETER to set a value between 1 and 60 s 5 3 ACTIVATION TIME FOR RELAY 2 By accessing the item ton2 it is possible to select the activation time of the relay ...

Page 3: ... already memorized LoWPW Supply voltage too low INI It appears when the memory is initialized MODE 1 DUAL INDEPENDENT OUTPUTS MODE 1 Dual indipendent outputs Program the transmitter 1 on the relay 1 The transmitter 1 activates the relay 1 for the TON1 time Program the transmitter 2 on the relay 2 The transmitter 2 activates the relay 2 for the TON2 time PROGRAMMING STEP BY STEP 1 Press briefly the...

Page 4: ...e TON1 time Then after the TDLY time they activate the relay 2 for the TON2 time PROGRAMMING STEP BY STEP 1 Press briefly the P1 button The display shows rad1 2 Press the button of the transmitter 1 The display shows done 3 To quit press briefly the P1 button 4 To enter the menu press briefly the P3 button 5 Set the item funCt to 2 6 Press briefly the P3 button 7 Set the ton1 time to the desired v...

Page 5: ... time they activate the relay 1 for the TON1 time PROGRAMMING STEP BY STEP 1 Press briefly the P1 button The display shows rad1 2 Press the button of the transmitter 1 The display shows done 3 Press the button of the transmitter 4 The display shows done 4 To quit press briefly the P1 button 5 Press briefly the P2 button The display shows rad2 6 Press the button of the transmitter 2 The display sho...

Page 6: ...fly the P1 button 5 Press briefly the P2 button The display shows rad2 6 Press the button of the transmitter 2 The display shows done 7 Press the button of the transmitter 3 The display shows done 8 To quit press briefly the P2 button 9 To enter the menu press briefly the P3 button 10 Set the item funCt to 4 11 Press briefly the P3 button 12 Set the ton1 time to the desired value 13 Press briefly ...

Page 7: ...ith Access Control or Time Clock The transmitters activate the relay 2 for the TON2 time only with the relay 1 activated PROGRAMMING STEP BY STEP 1 Press briefly the P1 button The display shows rad1 2 Give a command with the Access Control or Timed Clock The display shows done 3 To quit press briefly the P1 button 4 Press briefly the P2 button The display shows rad2 5 Press the button of the trans...

Page 8: ...tion of Transmitter Solutions if the product does not operate correctly due to a defective component This warranty does not extend to a the receiver case which can be damaged by conditions outside the control of Transmitter Solutions WARRANTY MODE 6 LATCHED MODE OPTION 2 MODE 6 Latched mode 2 You must program the transmitters on the relay 1 The transmitter activates the relay 1 for the TON1 time T...

Reviews: