1/8
6-1620026 rev.P4 22/02/2016
1
2
2 CHANNEL RECEIVER
3
1 2 3
8
7
6
5
4
RELAY 1
RELAY 2
P2
P1
P3
POTENTIOMETER
DISPLAY
OUT1
OUT2
MEMORY
RADIO MODULE
NC2
COM2
NO2
NC1
COM1
NO1
12-24 V
HIVE-DX
Receiver Rolling Code, 2 channels with dry contact relay output 20A a 12 Vdc. Programming up to 800 transmitters.
Power supply 12-24 Vac/dc with automatic selection of the voltage, frequency 433.92Mhz.
To program the trasmitter to the relay 1, follow the following steps:
1.
Press briefly the P1 button. The display shows
rad1
.
2. Press the button of the transmitter you want to memorize. The display shows
donE
.
3. The receiver is still in programming mode and ready for a new transmitter.
4.
To exit the receiver from program mode, press briefly the P1 button or wait 10s of inactivity. If it quits by timeout, the display shows the
number of transmitters already memorized.
To associate the trasmitter to the relay 2, follow the following steps:
1.
Press briefly the P2 button. The display shows
rad2
.
2. Press the button of the transmitter you want to memorize. The display shows
donE
.
3. The receiver waits for a new transmitter.
4.
To quit, press briefly the P2 button or wait 10s of inactivity. If it quits by timeout, the display shows the number of transmitters already
memorized.
Note: if the transmitter is already memorized, the display shows
fnd1
(associated to the 1st relay) or
fnd2
(associated to the 2nd relay) and then
it exits from the process.
ATTENTION: a programmed button can not be memorized in both the relays. To change the associated relay, remove the transmitter associated
to the button from the memory and then make again the learning process.
NOTE: the programmed button of the transmitter will maintain the associated relay for all the functioning modes.
DESCRIPTION
PROGRAMMING OF THE TRANSMITTERS
To delete all the trasmitters from the relay 1, follow the following steps:
1.
Press briefly the P1 button.
2. When the display shows
C1CLR
and the OUT1 led blinks fast for 3s, release the button. The transmitters have been deleted from the relay 1.
To delete all the trasmitters from the relay 2, follow the following steps:
REMOVAL OF THE TRANSMITTERS
TERMINAL BOARDS
1-2:
power supply,
12-24 Vdc-Vac
3-4:
relay 1, N.O. contact.
4-5:
relay 1, N.C. contact.
6-7:
relay 2, N.O. contact.
7-8:
relay 2, N.C. contact.
Code
Rolling Code
Max transmitters
800
Power supply
12-24 Vac/dc
Consumption (12Vdc) 27mA (standby)
110mA (2 relay)
Channels
2 (NO or NC contact)
Frequency
433.92 MHz
Range (in open space) 80-100m*
Relay contact
12A at 12 Vdc
Temperature
-10...55°C
*The range is influenced by the type of transmitter,
antenna and radio interferences.
Thank you for choosing this Transmitter Solutions product.