7/8
6-1620026 rev.P4 22/02/2016
1
2
3
8
7
6
5
4
RELA
Y 1
RELA
Y 2
P2
P1
P3
PO
TENTIOMETER
DISPLA
Y
OUT1
OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Time Clock
or
Access Control
12-24 Vac/Vdc
Power for Strike
Door operator
Electric Strike
Transmitter
PUSH
TO OPEN
12
MODE 5 - LATCHED MODE OPTION (1)
MODE 5 - Latched mode 1
Program Access Control (or Time Clock) on the relay 1 and the transmitters on the relay 2.
Access Control (or Time Clock) activates the relay 1 with a Step-by-Step command. To deactivate the relay 1, give another command with Access
Control (or Time Clock).
The transmitters activate the relay 2 for the
TON2
time, only with the relay 1 activated.
PROGRAMMING - STEP BY STEP
1.
Press briefly the P1 button. The display shows
rad1
.
2.
Give a command with the Access Control (or Timed Clock). The display shows
done
.
3.
To quit, press briefly the P1 button.
4.
Press briefly the P2 button. The display shows
rad2
.
5. Press the button of the transmitter. The display shows
done
.
6.
To quit, press briefly the P2 button.
7.
To enter the menu, press briefly the P3 button.
8. Set the item
funCt
to
5
.
9.
Press briefly the P3 button.
10.
Press briefly the P3 button.
11. Set the
ton2
time to the desired value.
12.
Press briefly the P3 button.
13.
Press briefly the P3 button.
14.
Press briefly the P3 button.