K) Egress Delay & Warning –
Installer Programming
(Default: Instant, No warning)
Loca�on
Delay Op�ons
Confirm
Comments
0 to 4
Five delay op�ons for opera�ng Output 1 with egress bu�on:
0 – Instant ac�va�on, no delay and warning
(default)
1 – Momentary contact, 5 seconds delay with warning
2 – Momentary contact, 10 seconds delay with warning
3 – Hold contact, 5 seconds delay with warning
4 – Hold contact, 10 seconds delay with warning
L) Exit Programming Mode
Confirm
Comments
It is always necessary to set keypad back to normal opera�ons a�er programming
2) Recording Super User Code –
User Programming
(No Default Codes)
Loca�on
Entry of Code
Confirm
Comments
4 digits fixed
Owner’s Mul�-task User Code
3) Recording the Visitor Codes –
User Programming
(No Default Codes
)
Loca�on
Opera�on Time
Entry of Code
Confirm
Comments
00 to 99 4 digits fixed
visitor code for opera�ng Output 1.
Opera�on Time:
00 = One �me use only
01 to 99 = Valid within �me limit of 1-99 hours
Programming Examples for “Single-User Mode”
1.
Set keypad to programming mode with the Ex-factory Master Code
0 0 0 0
or your Master Code if
it was changed:
2.
Refresh the keypad to Single-User Mode with Refreshing code
8 9 0 0
:
3.
Program a new Master Code
3 2 8 9
for the keypad:
4.
Program an User Code
8 3 2 1
for
output 1
:
5.
Program a Super User Code
2 5 8 0
:
6.
Program a Visitor Code
2 3 0 8
with Time-Limit of
8 hours
:
7.
Exit programming mode by pressing the
8
25