E) Configura�on of Output 1 for Electric Lock –
Installer Programming
(Default: Fail-Secure)
Loca�on
Type of Lock
Confirm
Comments
Fail-Secure electric lock (energized to unlock)
Fail-Safe electric lock (de-energized to unlock)
F) False Code Lock-up & Repor�ng –
Installer Programming
(Default: 10 tries / 30 seconds)
Loca�on
Lock-up Modes
Confirm
Comments
1
10 successive false codes, keypad locks during 30 seconds
(default)
5 to 10
Selectable of 5 to 10 false code, keypad locks during 15 minutes.
Locking can be released at any �me with Super User Code
00
Disappearance of all the above securi�es
●
Opera�on Voltage:
12V DC, 11-15V DC
●
Opera�on Current
:
Quiescent - 16mA
Maximum - 50mA
●
Opera�on Modes:
a) Mul� User Mode
--
100 user codes for output 1 (user number 00-99), Auto or Manual Code
Entry
b) Single User Mode
-- 1 user code for each output and the special func�ons, Auto or Manual Code
Entry
●
User Code Combina�ons:
a) Single User Mode -- 10,000 (User Code fixed at 4 digits)
b) Mul� User Mode -- Over 1 Million (User Code 4-8 digits programmable)
●
Input Sensing Terminals:
Egress Input -- Normally open referring to (–) ground
●
Output Contacts:
OUTPUT 1 : Solid State Fail-secure or Fail-safe, 3A / 12VDC. Ra�ng
●
Tamper Switch Contact:
Normally Closed Dry Contact, 50mA / 24VDC Max.
●
Auto Refreshing Time During Code Entry:
a) Eash Digit Maximum Entry Time Limit -- 10 seconds
b) Eash Code Maximum Entry Time Limit -- 30 seconds
●
Opera�ng Environment:
In-door use only
●
Opera�on Temperature:
-20°C to +70°C
●
Ambient Humidity:
5-95% rela�ve humidity (non-condensing)
●
Dimensions:
117(H) X 72(W) X 42(D)mm
●
Weight:
140g net
Specifications are subject to change for modification without notice
SPECIFICATIONS
G) Output Ac�va�on (Door Open) Announcer –
Installer Programming
(Default: 1 long beep)
Loca�on
Func�on Codes
Confirm
Comments
H) User Code Entry Modes (Auto or Manual) –
Installer Programming
(Default: Manual)
Loca�on
Func�on Codes
Confirm
Comments
I) Pacifier Tones (Key-press beeps) –
Installer Programming
(Default: ON)
Loca�on
Func�on Codes
Confirm
Comments
Pacifier tone OFF, good for silent environment
Pacifier tone ON for every key-press
(default)
J) Main LED Flashing ON-OFF –
Installer Programming
(Default: Flashing)
Loca�on
Func�on Codes
Confirm
Comments
No no�fica�on.
2 short-beep is given when the door lock is opened.
1 second long beep no�fica�on is given when the door lock is
opened. It is good for locking device give no sound when it
ac�vates. Such as a magne�c lock
(default)
Manual Entry Mode requires to enter
bu�on a�er the user
codes.
It is NOT necessary to set the Master Code and all User
Codes in the same digit length. They can be 4-8 digits mixed
arbitrary
(default)
Auto Entry Mode does not need to enter
bu�on a�er the user
codes. However, All the User Codes MUST be in the same digit
length of the Master Code and they can be 4-8 digits
Main LED OFF during system standby, good for people do not like
flashing LED at night
Main LED flashing during system standby
(default)
7
26