Operation :
1. Operate Output 1 in momentary mode of 5 seconds using user code
8 3 2 1
that was
programmed
previously:
----------- Output 1 operates for 5 seconds
2. Operate Output 1 in Start / Stop mode using user code
8 3 2 1
that was programmed previously:
-------- Output 1 start / stop in toggle with the same user code
3. Operate Output 1 in Start / Stop mode with the 2 digit Accelerated code using user code
8 3 2 1
that was programmed previously:
----------------- Output 1 starts with Accelerated Code
----- Output 1 stops with Full User Code
NOTE:
●
The purpose of the accelerated Code --
Start / Stop mode with accelerated code can be
considered as two user codes with one for star�ng and the other for stopping the output. Owner
can give the accelerated code to the staff to start a system (for example, an alarm system). The
staff can only start the system but can not stop it. Only the owner can stop the system with the
full user code.
●
The Super User Code is always valid to Start / Stop the output.
Super User Code
------- Output 1 Ac�vates or De-ac�vates
The output 1 can be programmed to trigger with the following op�ons. for a programmed length of
�me from 1 to 999 seconds; or to trigger ON and OFF in toggle with a user code; or to trigger ON
with an accelerated start code and OFF with an full digit user code.
Loca�ons
Time Length
Confirm
A)
1 – 999
B)
C)
D)
NOTE:
Programming Loca�ons:
●
Loca�ons 40, 41, 42 and 43
for Output 1
Programming Options for Output 1
(See “Programming Summary Chart” Section D for more information) :
A) Loca�on 40 : Momentary Mode with �me length from 1 to 999 seconds (Default = 1 second)
The relay outputs can be programmed to work for a �me length from
to
seconds to
cope with the door opening required.
B) Loca�on 41 : Start / Stop Mode (toggle)
The relay outputs can be programmed to trigger ON (start) and OFF (stop) with a user code.
C) Loca�on 42 : Start / Stop Mode (toggle) with 2-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 2 digits of a user code and
OFF with a full user code.
Example:
a) User Code
8 3 2 1
is a full code, then the first 2 digit
8 3
is the accelerated code.
b) User Code
5 4 3 2 1
is a full code, then the first 2 digit
5 4
is the accelerated code.
D) Loca�on 43 : Start / Stop Mode (toggle) with 3-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 3 digits of a user code and
OFF with a full user code.
Example:
a) User Code
5 4 3 2 1
is a full code, then the first 3 digit
5 4 3
is the accelerated code.
b) User Code
9 2 7 0 5 3
is a full code, then the first 3 digit
9 2 7
is the accelerated code.
Configura�on of Output Modes for Output 1
(Loca�ons 40–43)
Programming Examples:
1. Set keypad to programming mode with master code and
key. Taking the previous programmed
master code
3 2 8 9
as example here:
2. Set Output 1 in momentary mode of 5 seconds:
3. Set Output 1 in Start / Stop Mode:
4. Set Output 1 in Start / Stop Mode with 2-digit Accelerated Start Code:
5. Exit programming mode by pressing the
16
17