Super User Code is a mul�-task user code for ac�va�ng the output 1 and opera�ng the special 

func�ons of Output 1.

Loca�ons

        Super User Code       

Confirm



   

4 - 8 Digits

 

 

NOTE:

 

The super user code can be 4-8 digits long in manual code entry mode; but must has the same 

length as the master code if the keypad is in auto code entry mode.

 

Super user code and Egress Bu�on are excluded from any system opera�on inhibit and lock-up; 

they are always valid for door open at any�me for safety.

 

See “Programming Summary Chart” Sec�on C – 2 for more informa�on

 

See informa�on on 

Loca�on 82

 concerning digit length in Auto and Manual code entry modes.

Programming Example :

1. Set keypad to programming mode with master code and

  

 

 key. Taking the previous programmed 

master code 

3 2 8 9

 as example here:

                  



 

2. Program 2 5 8 0 as Super User Code:

                  

     

3. Exit programming mode by pressing the 

 

Operation :

1) Opera�ng Output 1

Super User Code is just like a normal user code. Simply key-in the code with a specific output 

number of the desired output. Super User Code can also be used to reset an output opera�ng 

with long �mer instantly at any�me required.

  

     ------- Output 1 Ac�vates or De-ac�vates

 Programming The Super User Code

(Loca�on 45)

Pacifier tones are the beep tones from the keypad to confirm the code entry successfully or not. 

Pacifier tone ON-OFF does not impact the sound mode of the “Output Ac�va�on Announcer” at 

Loca�on 81

Loca�ons

        

Func�on Op�ons

         

Confirm



             

0 or 1

 

Programming Options:

 

  -- All pacifier tones OFF, good for place needs silent environment.

  -- Pacifier tones enabled, the tones indicate opera�on status of the keypad; such as 1 beep for 

successful key entry and 5 beeps for unsuccessful code entry 

(Default)

.

Pacifier Tones ON-OFF

                                          (Loca�on 83)

The status LED typically flashes while the keypad is in standby. Some people find it is annoying 

especially at the night �me. The LED can be ON or OFF with the se�ng here.

Loca�ons

        

Func�on Op�ons

         

Confirm



            

0 or 1

   

 

Programming Options:

  

-- The status LED flashing is OFF. It is good for the people do not like a flashing light at night. 

  

-- The status LED flashes all the �me in standby mode 

(Default)

 Main Status LED Flashing ON-OFF

(Location 84) 

12

21

Summary of Contents for DOLKSS1KB

Page 1: ...S1KB Programming Installation Manual FOR ELECTRIC LOCK INSTALLTION SELF CONTAINED DIGITAL ACCESS CONTROL KEYPAD 2480 South 3850 West Suite B Salt Lake City UT 84120 866 975 0101 866 975 0404 fax www t...

Page 2: ...The Super User Code Programming The Visitor Codes Dele ng User Codes Other Func on Codes Con gura on of Output Modes for Outputs 1 Con gura on of Output 1 for Electric Lock False A empt System Lock u...

Page 3: ...The Super User Code Programming The Visitor Codes Dele ng User Codes Other Func on Codes Con gura on of Output Modes for Outputs 1 Con gura on of Output 1 for Electric Lock False A empt System Lock u...

Page 4: ...olling security systems automatic operators and machinery The DK 9521 offers single relay output and that the DK 9522 offers dual relay output DK 9521 DK 9522 consists two application softwares of Sin...

Page 5: ...lock to these terminals directly with correct polarity The output has been set for Fail Secure Electric Lock in Default It is programmable for Fail Secure energized to open or Fail Safe de energized t...

Page 6: ...eep 2 Beeps 5 Beeps Continuous Beeps 1 second Long Beep ON 1 Flash 2 Flashes 5 Flashes Continuous Flashes 1 Flash in 2 seconds interval 2 Successful key entry 3 Successful code entry 4 Unsuccessful co...

Page 7: ...ments 1 to 999 STANDARD PROGRAMMING SUMMARY CHART Output 1 Momentary Mode from 1 to 999 seconds default 1 second Output 1 Start Stop Mode toggle Output 1 Start Stop Mode toggle with 2 digit Accelerate...

Page 8: ...mit 30 seconds Opera ng Environment In door use only Opera on Temperature 20 C to 70 C Ambient Humidity 5 95 rela ve humidity non condensing Dimensions 117 H X 72 W X 42 D mm Weight 140g net Specifica...

Page 9: ...s Loca on Entry of Code Con rm Comments 4 digits xed Owner s Mul task User Code 3 Recording the Visitor Codes User Programming No Default Codes Loca on Opera on Time Entry of Code Con rm Comments 00 t...

Page 10: ...ed data in the programming loca ons A er the keypad is in programming mode a new master code may be programmed to replace the one that was forgo en A Enter Programming Mode with Master Code Exit Facto...

Page 11: ...new owner who bought a house with a keypad installed The procedures are as follows 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as examp...

Page 12: ...ad The user codes are always the rst priority to operate output 1 to actuate the door lock It is not necessary to do anything if egress delay is not required Just leave the egress bu on on its default...

Page 13: ...speci c output number of the desired output Super User Code can also be used to reset an output opera ng with long mer instantly at any me required Output 1 Ac vates or De ac vates Programming The Sup...

Page 14: ...Disable All User Codes for Door Lock Actua on To enhance security a er o ce hour or while nobody inside house owner can manually stop the opera on of Output 1 to prevent users from accessing the prote...

Page 15: ...alid dura on Loca ons User ID Valid Dura on Entry of Code Con rm 0 9 00 or 01 to 99 Visitor Code NOTE Visitor codes can be 4 8 digits long in manual code entry mode but must have the same length as th...

Page 16: ...elect the right one for your applica on environment The keypad has been designed compa ble with both types of lock with an appropriate code of the type of lock Loca ons Type of Lock Con rm 0 or 1 Prog...

Page 17: ...ogramming Options for Output 1 See Programming Summary Chart Section D for more information A Loca on 40 Momentary Mode with me length from 1 to 999 seconds Default 1 second The relay outputs can be p...

Page 18: ...ogramming Options for Output 1 See Programming Summary Chart Section D for more information A Loca on 40 Momentary Mode with me length from 1 to 999 seconds Default 1 second The relay outputs can be p...

Page 19: ...elect the right one for your applica on environment The keypad has been designed compa ble with both types of lock with an appropriate code of the type of lock Loca ons Type of Lock Con rm 0 or 1 Prog...

Page 20: ...alid dura on Loca ons User ID Valid Dura on Entry of Code Con rm 0 9 00 or 01 to 99 Visitor Code NOTE Visitor codes can be 4 8 digits long in manual code entry mode but must have the same length as th...

Page 21: ...Disable All User Codes for Door Lock Actua on To enhance security a er o ce hour or while nobody inside house owner can manually stop the opera on of Output 1 to prevent users from accessing the prote...

Page 22: ...speci c output number of the desired output Super User Code can also be used to reset an output opera ng with long mer instantly at any me required Output 1 Ac vates or De ac vates Programming The Sup...

Page 23: ...ad The user codes are always the rst priority to operate output 1 to actuate the door lock It is not necessary to do anything if egress delay is not required Just leave the egress bu on on its default...

Page 24: ...new owner who bought a house with a keypad installed The procedures are as follows 1 Set keypad to programming mode with master code and key Taking the previous programmed master code 3 2 8 9 as examp...

Page 25: ...ed data in the programming loca ons A er the keypad is in programming mode a new master code may be programmed to replace the one that was forgo en A Enter Programming Mode with Master Code Exit Facto...

Page 26: ...s Loca on Entry of Code Con rm Comments 4 digits xed Owner s Mul task User Code 3 Recording the Visitor Codes User Programming No Default Codes Loca on Opera on Time Entry of Code Con rm Comments 00 t...

Page 27: ...mit 30 seconds Opera ng Environment In door use only Opera on Temperature 20 C to 70 C Ambient Humidity 5 95 rela ve humidity non condensing Dimensions 117 H X 72 W X 42 D mm Weight 140g net Specifica...

Page 28: ...ments 1 to 999 STANDARD PROGRAMMING SUMMARY CHART Output 1 Momentary Mode from 1 to 999 seconds default 1 second Output 1 Start Stop Mode toggle Output 1 Start Stop Mode toggle with 2 digit Accelerate...

Page 29: ...eep 2 Beeps 5 Beeps Continuous Beeps 1 second Long Beep ON 1 Flash 2 Flashes 5 Flashes Continuous Flashes 1 Flash in 2 seconds interval 2 Successful key entry 3 Successful code entry 4 Unsuccessful co...

Page 30: ...lock to these terminals directly with correct polarity The output has been set for Fail Secure Electric Lock in Default It is programmable for Fail Secure energized to open or Fail Safe de energized t...

Page 31: ...olling security systems automatic operators and machinery The DK 9521 offers single relay output and that the DK 9522 offers dual relay output DK 9521 DK 9522 consists two application softwares of Sin...

Page 32: ...S1KB Programming Installation Manual FOR ELECTRIC LOCK INSTALLTION SELF CONTAINED DIGITAL ACCESS CONTROL KEYPAD 2480 South 3850 West Suite B Salt Lake City UT 84120 866 975 0101 866 975 0404 fax www t...

Reviews: