Criteria for Programming
(1) The keypad
MUST
be in Programming Mode for making Se�ng and Data Changes.
(2) Programming can be accomplished in workshop or at the installa�on site. All data are stored in a
non-vola�le memory and will not be lost in power off.
(3)
DO NOT
disconnect the keypad from power while in programming mode; otherwise could cause
a keypad memory error.
Enter and Exit Programming Mode
It is necessary to set the keypad in programming mode with the Master Code for all programming.
1. Enter programming mode with the master code and confirm it with
key.
For the owner’s convenience in programming at the first �me, a Master Code
has
been set before exit-factory.
Master Code
Confirm
--- Keypad is now in programming mode
2. Use the programming instruc�ons stated in “Programming Summary Chart”
to make change of
the keypad data. Programming can be done con�nuously one by one on the Loca�ons required
un�l finish.
3. Exit the programming mode by pressing the
key a�er all the required programming is finished.
NOTE:
●
For security reason, owner should program a new master code to replace the exit-factory master
code.
●
Once a new master code is programmed, the old master code is replaced.
●
Use DAP jumper to set keypad to programming mode if master code is forgo�en. See DAP
Jumper descrip�on for the details.
The DAP Jumper (Direct Access to Programming Mode) – If Master Code is Forgo�en
If the master code is forgo�en, use the DAP jumper (located on the main circuit board) to override
the forgo�en code and permit the keypad direct entry into programming mode. Apply the
procedures precisely as follows.
1. Disconnect the power supply.
2. Move the DAP jumper from OFF to ON.
3. Reconnect the power supply.
The keypad will start beeping.
4. Move the DAP jumper back to OFF posi�on.
The keypad will stop beeping as soon as the jumper is removed.
5. The keypad is now in the programming mode, ready to receive new programming data.
6. Re-program the keypad with the available op�ons shown on the “Programming Summary Chart”.
●
The opera�on of DAP jumper is for se�ng the keypad into programming mode only. It does not
affect the stored data in the programming loca�ons.
●
A�er the keypad is in programming mode, a new master code may be programmed to replace the
one that was forgo�en.
A) Enter Programming Mode with Master Code
(Exit-Factory Master Code: 0 0 0 0)
Entry of Master Code
Confirm
Comments
Set system to Programming Mode
NOTE:
Factory has put a master code
into the keypad before exit-factory, owner may take it
for first �me use.
B) System Refreshing to Single User Mode –
Installer Programming
(Default: 8 9 0 0, Single-user mode)
Refresh Code
Confirm
Comments
Clear all previously stored data and set keypad back to default values except
Master Code
C) Code Entries –
User Programming
1) Recording Master Code and User Codes –
User Programming
(No Default Codes)
Loca�ons
Entry of Codes
Confirm
Comments
4 digits fixed
Owner’s Master Code for se�ng system to programming mode
4 digits fixed
User Code for opera�ng Output 1
Programming Summary Chart for “Single-User Mode”
SET KEYPAD TO SINGLE USER MODE (to whom it may require)
This keypad also consists of a simplified version so�ware for code entry. It is single user mode for
those users only need one each user code for output 1 and the special func�ons.
Once the keypad is in single user mode, there is no User ID required for the codes, just simply enter
the code to each Loca�ons directly.
Single user mode is prepared for those users who need simple func�on and use the default values
for their keypad only. Please ignore this sec�on if it is not suitable for your applica�on.
Important Notes:
●
All user codes and master code must be 4 digits. The codes of more than 4 digits will be invalid.
●
Change the master code to 4 digits before refreshing the keypad to single user mode. Otherwise,
refreshing will be refused.
●
Refreshing takes 2-3 seconds to complete. Do not enter any code during refreshing un�l 2
confirma�on beeps are heard.
●
The keypad will be in auto code entry mode in default a�er it is refreshed to single user mode.
●
The keypad can be changed back to standard mul�-user mode with the system refreshing code 8 9 0 1.
●
Single user mode simplifies the procedures for code entry only. All programming procedures for
other features are exactly the same like in mul�-user mode and not affected.
●
See summary chart for the
“Single-User Mode”
programming procedures.
SETTING & PROGRAMMING
DAP
ON OFF
9